Influence of the indirect restoration design on the fracture resistance: a finite element study

Abstract

Objectives

To establish a three-dimensional (3D) finite element (FE) model of a maxillary first premolar and to evaluate the stress generated on the tooth (dentine) and on the indirect composite resin restorations by occlusal forces.

Methods

An embedded intact maxillary first premolar tooth was sliced serially and scanned digitally parallel to the occlusal surface. The 64 images were assembled in a 3D FE mesh and exported to generate a 3D solid tooth model. Simulated, adhesively cemented indirect mesial-occlusal-distal (MOD) inlays of 2 mm (I1), 3 mm (I2) and 4 mm (I3) in width, and MOD onlays with occlusal cusp coverage of 2 mm (O1) and 3 mm (O2) in depth were created. The peak von Mises stress values in the five tooth models resulting from static vertical and oblique occlusal forces (300 N) were evaluated using Patran FE software.

Results

The peak stress values generated by vertical occlusal force generated in dentine of I1, I2, I3, O1 and O2 restoration were 67, 32, 29, 38 and 27 MPa, respectively, and those generated by oblique occlusal force were 52, 114, 168, 54 and 55 MPa, respectively. The peak von Mises stress values in I1, I2, I3, O1 and O2 restoration subjected to oblique occlusal loading were 79, 120, 1740, 1400 and 1170 MPa, respectively.

Conclusion

A 3D FE model of a maxillary first premolar was established. Simulated cemented composite resin onlay markedly reduces occlusal stress in the underlying dentine of large MOD preparation. Oblique occlusal force imparts substantially higher stress to large composite resin inlay than to the adjacent dentine.

Background

An increased interest in aesthetic dentistry and concerns about mercury in amalgam alloys have led to an increased demand from patients for metal-free restorations and a relatively simple way to restore their teeth [1]. Though the use of posterior direct composite resins is still the common practice, such restorations may lead to problems such as fracture and microleakage caused by polymerization shrinkage [2]. Those properties of direct resin may lead to postoperative sensitivity, marginal staining and secondary caries [3, 4]. Following secondary curing, indirect composite resin inlays and onlays generally show improvements in their degree of polymer conversion, mechanical properties, wear resistance and marginal microleakage [5, 6]. Correct tooth morphology also may be achieved with less difficulty for large indirect restorations.

However, the use of indirect inlays to replace failed mesial-occlusal-distal (MOD) direct placement restorations in premolar teeth is questionable on biomechanical grounds [6, 7]. Concerns arise from the fact that removing and replacing such defective intracoronal restorations can lead to a significant extension of the original preparations, with an increased size, isthmus width and cusp height [8, 9]. Occlusal forces on an inlay produce stresses along the sides and base of the restoration, which may fracture the tooth [10]. Covering the occlusal surface of the intracoronal MOD preparation with metal to form an onlay is found to greatly reduce the potentially damaging effects of the occlusal forces [11]. Tooth fractures occur less readily in intact posterior teeth than following cavity preparation [12, 13]. The width and depth of premolar preparations are important factors affecting tooth strength [14, 15]. The type of cavity preparation and materials also affect the extent of tooth fracture [16, 17].

Early finite element (FE) studies found that increased cavity dimensions were associated with increased stresses in the remaining tooth structure [1820]. More recent FE studies have evaluated several parameters of occlusal forces, MOD cavity preparation geometry and dental materials used to restore maxillary premolar teeth [20, 21]. Teeth restored with ceramic materials have showed a higher fracture resistance than those restored with composite resin in several FE studies [22, 23]. On the other hand, composite resin restorations like inlay and onlay also have their own fields of application. They are less costly, time-saving, and easy to remove when subsequent restorative treatment is necessary. Since composite resin has a lower fracture resistance than ceramics [22, 23], the optimization of cavity dimension becomes critical in making a successful resin restoration. Therefore, the question of how to control the dimension of the resin restoration was raised in the current study. Few FE studies have investigated the effects of different dimensions of resin inlay and onlay on risk of tooth fracture under different loading forces.

The objective of this study was to establish a 3D FE model of a human maxillary first premolar tooth and to use this model to evaluate the effects of (a) MOD inlay restorations of different occlusal isthmus widths and (b) MOD onlay restorations of different occlusal cusp coverage depths on the stresses generated within the tooth model and restorations from occlusal forces. The null hypothesis proposed is that, when subjected to either a vertical or oblique standardized static occlusal force, there are no marked differences present in the resulting peak von Mises stress values for different sizes of indirectly fabricated MOD composite resin inlays and onlays restoring a maxillary premolar tooth model.

Methods

An intact human maxillary first premolar tooth extracted for orthodontic reasons was selected as the generic model. The restored tooth was at risk for cuspal fracture in clinical practice [24]. The crown dimensions of the selected tooth were similar to average values [25].

The tooth was embedded in clear acrylic resin (ProBase®Cold, Ivoclar vivadent, PR Liechtenstein), then sliced serially at 0.3 mm increments along its long axis from cusp tip to root apex using a thin diamond saw (Isomet®Low Speed Saw, Buehler Ltd, IL, USA) with copious water cooling. Each of the 64 sections obtained was scanned from the occlusal side using a digital flatbed scanner (S2W4300/3300u, BenQ Asia Pacific Corp., Taipei, Taiwan), and the images were stored as BMP files with a resolution of 1200 dots per inch (dpi). The images were assembled in a 3D wire-frame mesh structure by means of a computer software program (Photoshop 7.0, Adobe Systems Inc., San Jose, CA, USA). The 3D curves were exported using proprietary software (Rhino™ 3D, McNeel North America, Seattle, WA, USA) to generate a maxillary first premolar solid tooth model (enamel, dentine, pulp chamber and periodontal ligament) by fitting the horizontal and vertical profiles. The solid model of the maxillary premolar was subsequently exported as XT files (Patran™ 2004, MSC Software Corp, Santa Ana, CA, USA) to establish the 3D FE model. Following proportional adjustments, a virtual reality image with a criss-crossing mesh was established.

The 3D solid model was used to create simulated MOD inlay preparations of three different occlusal widths: I1 (2.0 mm), I2 (3.0 mm), I3 (4.0 mm). The occlusal depth of each cavity preparation was 2.5 mm, and the gingival margins of the mesial and distal proximal boxes were placed 1.0 mm above the enamel-cemental junction. The cavity floors were flat, and the cavity walls had a 5° divergence angle. No cavosurface bevels were present (Fig. 1). The 3D solid model was also used to create simulated cusp coverage MOD onlay preparations of two different occlusal cusp coverage depths: O1 (2.0 mm) and O2 (3.0 mm) (Fig. 1). The original dimensions of each cavity preparation before cusp reduction were as for I3. An 80-µm-thick resin-based adhesive cement layer was established between the cavity walls and simulated indirectly fabricated proximal (Class II) composite resin restorations. A 130-µm-thick periodontal ligament was also established [26]. The solid models were imported into Patran 2004, redefined and meshed using a 10-noded tetrahedral element, resulting in 55,032 nodes and 37,010 elements. Sufficiently fine meshing was taken to ensure the mesh convergence of the results. Different material properties were assigned to the elements (Table 1) according to their volume definitions. All materials were assumed to be homogeneous and isotropic. Five different models were generated. To study the effects of different cavity designs, only one material of the restoration was defined to suppress interference from other factors. The boundary conditions were specified to be consistent with physiological conditions. They were set as fixed, vertical and horizontal displacements along root surfaces of the model that were restricted to simulate support from the alveolar bone [21] (Fig. 2).

Fig. 1
figure 1

3D models of the inlay and onlay restoration designs

Table 1 Properties attributed to the tooth structure and restorative material
Fig. 2
figure 2

Illustration of load and boundary conditions: a vertical loading; b oblique loading

Two types of static loading were used: (a) vertical loading on the occlusal surface perpendicular to the loading axis (Fig. 2a, b) oblique loading resolved into two oblique components acting perpendicularly to the inner cusp inclines, which lay at approximately 45° to the vertical loading axis (Fig. 2b). The force applied for both types of loading was 300 N [27]. The von Mises stress was used as the study variable, based on the distortion energy theory in engineering, using the formula \(\sigma_{v} = \sqrt[{}]{{\frac{{\left( {\sigma_{1} - \sigma_{2} } \right)^{2} + \left( {\sigma_{2} - \sigma_{3} } \right)^{2} + \left( {\sigma_{3} - \sigma_{1} } \right)^{2} }}{2}}}\) [28]. The equivalent stress \(\sigma_{v}\) is referred to as Von Mises stress. The variables \(\sigma_{1}\), \(\sigma_{2}\) and \(\sigma_{3}\) are referred to as the three principal stresses. Whatever the state of stress, when the ratio of the deformation reaches a critical value related to the property of the material, then the material begins to yield.

The peak von Mises stress was evaluated under two loading conditions (oblique and vertical) for each of five restorations (3 inlays and 2 onlays). Subsequently, the peak von Mises stress in term of oblique loading condition was analysed on dentine and restorations, respectively. In addition, the von Mises stress patterns under two loading conditions (vertical and oblique) were also assessed.

Results

Figure 3 shows the peak von Misses stress value of dentine for the five models subjected to vertical and oblique occlusal loading. I1 has a slightly lower stress value (52 MPa) under oblique loading than under vertical loading (67 MPa). I2 has an obviously higher stress value under oblique loading (114 MPa) than under vertical loading (32 MPa). I3 has a similar pattern to I2. Similar patterns were also observed in both O1 and O2; namely, stress value was slightly higher under oblique loading than under vertical loading. In general, Peak von Mises stress values in the dentine increased for the oblique force but decreased for the vertical force, with increasing inlay cavity width in particular and with increasing onlay cusp coverage depth. Except for the 1.0-mm-wide I1, all of the other models demonstrated higher stress values resulting from oblique loading than from vertical loading. When subjected to an oblique force, peak von Mises stress values in the inlay restorations increased markedly for the 4.0-mm-wide I3 (168 MPa), being 3.25 times that for I1 (52 MPa) and 1.47 times that for I2 (114 MPa). Peak stress values also were high in the two onlay restorations, though they were lower for O2, which had an increased cusp coverage depth of 3.0 mm.

Fig. 3
figure 3

Peak von Mises stress values in the dentine for the five models subjected to vertical and oblique occlusal loadings of 300 N

For the five models, when subjected to an oblique force, the peak von Mises stress values of the restoration and dentine are shown in Fig. 4. I1 and I2 show much less stress, not only on the restoration but also on the dentine, whereas the very wide I3 and the two onlays demonstrated much higher stress values in the restorations than in the dentine.

Fig. 4
figure 4

Peak von Mises stress values in the dentine and restorations for the five models subjected to oblique occlusal loadings of 300 N

The distribution of the von Mises stress patterns in the five models for the vertical and oblique forces (300 N) are illustrated in Figs. 5 and 6, respectively. The stress distributions of the inlay groups are similar, even with the vertical occlusal loadings and high stress located on both buccal and lingual cusps. In the onlay groups, however, the stress on the cusps has been remarkably reduced. This may reduce the risk of tooth fracture. Moreover, the enamel-dentine junction and bottom of the cavity are also the area with high stress under vertical force. For an oblique force, the highest stresses in the cuspal dentine were associated with the widest inlay preparation.

Fig. 5
figure 5

Von Mises stress patterns for the five models subjected to vertical occlusal loadings of 300 N; arrows indicate the locations of peak von Mises

Fig. 6
figure 6

Von Mises stress patterns for the five models subjected to oblique occlusal loadings of 300 N; arrows indicate the locations of peak von Mises

Discussion

Indirect restorations are those that fit within the anatomic contours of the clinical crown of a tooth. They can be classified as inlays or onlays, depending on whether they have an occlusal veneer or not [29]. The biomechanical study of a tooth with an indirect restoration presents difficulties in many respects, such as the complexity of the tooth’s structure, restorative materials, boundary condition, cavity shape, dimensions and state of stress [20]. This study investigated the stress distribution of indirect restorations of different designs by means of an FE method. The reality was only reproduced by a mathematical approach using typical material properties, loading and boundary conditions.

To keep the simplification effect as low as possible, calculations were not limited to the tooth and the restorations but extended to other structures such as the periodontal ligament and the alveolar bone. Though computerized tomography techniques are available for anatomical and structural data collection [30, 31], obtaining digital images of the premolar tooth in the present study was far simpler. Conventional computer-aided-design (CAD) software is able to represent the curvature of the real object [18, 32]. One of the concerns of the study is that the fracture is due to a static loading, while fatigue phenomena should be considered. In the current study, the conditions and testing of the stress distribution of the materials and tooth have been simplified to instant force. Therefore, the results cannot be extrapolated to the in vivo situation, and caution should be exercised in their interpretation.

Based on the results of this study, the null hypothesis was not accepted. In the present study, as the size of the cavity and the inlay increased, the stress caused by oblique occlusal loading on the dentine increased more dramatically than that caused by vertical occlusal loading. This indicated that oblique occlusal forces in particular imparted high stresses to adhesively cemented large MOD composite resin inlays and onlays and, to a much lesser extent, to the functional remaining cusp structures present with the large inlay restoration (~160 MPa). Moreover, when a tooth with an onlay was subjected to oblique forces, the stresses could be effectively transferred to the composite resin onlay restorations rather than to the underlying tooth structure. Under oblique occlusal loading, the peak von Mises stress values in the dentine increased with the width of the inlay cavity width from I1 to I3. When the inlay was replaced by an onlay with the same cavity width, the peak von Mises stress on dentine decreased. Moreover, in large inlays and onlays under oblique occlusal force, the stress in restorations was substantially higher than the stress in dentine. This suggested that the onlay restorations offer protection to the underlying tooth structure. The Young’s modulus of the composite resin used is 14 GPa, which is similar to that of dentine (18 GPa) and less than that of porcelain (70 GPa) or Ni–Cr alloy (204 GPa) [33]. It was also shown that a less rigid restoration could relax the applied stress by means of greater elastic deformation [34]. The less rigid composite resin shows that a greater elastic deformation would result in a lower deformation of the cusps [34]. Therefore, the risk of tooth fracture associated with large cavity preparations could be reduced by the overlaying of the vulnerable cusps with proper restorative materials [35].

Different load conditions result in different concentrations of stress on a tooth. Oblique occlusal force induces a high stress concentration on the cusps and increases the risk of tooth fracture (Fig. 6). In inlay groups, the stress in dentine under oblique force was higher than that under vertical force, and the difference increased with the width of the inlay. The tooth cusps become narrow when the width of the inlay is large [22, 36]. The stress on dentine reduced remarkably when the cavity was restored by O1, which had the same width as I3 (Fig. 3). The high stress concentration on the cusps when they were restored by inlays was also relieved in onlays. Therefore, this study confirmed that preparing the cusps and making an onlay restoration for a large cavity could reduce the high stress generated by occlusal loading. In addition, the difference of stress values and distributions was not significant in the two onlay groups, therefore O1, which had a small depth, was preferred because it was more conservative than O2, which had a large depth.

Conclusions

In this study, a 3D FE model of a maxillary first premolar tooth was established for evaluation of the stresses generated within the tooth and the indirect restoration from occlusal forces. Oblique occlusal force imparted substantially higher stress to large composite resin inlay than to the adjacent dentine. Onlay preparation reduced occlusal stress and the risk of cusp fracture associated with large cavity preparation. Therefore, an onlay with cusp coverage should be used for restoration when the width of the cavity reaches 4 mm.

Abbreviations

MOD:

mesial occlusal distal

FE:

finite element

CAD:

computer-aided design

References

  1. Fuks AB. The use of amalgam in pediatric dentistry. Pediatr Dent. 2002;24:448–55.

    Google Scholar 

  2. Giachetti L, Scaminaci Russo D, Bambi C, Grandini R. A review of polymerization shrinkage stress: current techniques for posterior direct resin restorations. J Contemp Dent Pract. 2006;7:79–88.

    Google Scholar 

  3. Ferracane JL. Resin composite–state of the art. Dent Mater. 2011;27:29–38.

    Article  Google Scholar 

  4. Manhart J, Kunzelmann KH, Chen HY, et al. Mechanical properties and wear behavior of light-cured packable composite resins. Dent Mater. 2000;16:33–40.

    Article  Google Scholar 

  5. Chang HS, Kim JW. Early hardness and shear bond strength of dual-cure resin cement light cured through resin overlays with different dentin-layer thicknesses. Oper Dent. 2014;39:398–406.

    Article  Google Scholar 

  6. Fron Chabouis H, Smail Faugeron V, Attal JP. Clinical efficacy of composite versus ceramic inlays and onlays: a systematic review. Dent Mater. 2013;29:1209–18.

    Article  Google Scholar 

  7. ADA Council on Scientific Affairs. Direct and indirect restorative materials. J Am Dent Assoc. 2003;134:463–72.

    Article  Google Scholar 

  8. Hernandes NM, Catelan A, Soares GP, et al. Influence of flowable composite and restorative technique on microleakage of class II restorations. J Investig Clin Dent. 2014;5:283–8.

    Article  Google Scholar 

  9. Lai GY, Zhu LK, Li MY, et al. An in vitro study on the secondary caries-prevention properties of three restorative materials. J Prosthet Dent. 2013;110:363–8.

    Article  Google Scholar 

  10. Keown AJ, Lee JJ, Bush MB. Fracture behavior of human molars. J Mater Sci Mater Med. 2012;23:2847–56.

    Article  Google Scholar 

  11. van Dijken JW. Direct resin composite inlays/onlays: an 11 year follow-up. J Dent. 2000;28:299–306.

    Article  Google Scholar 

  12. Sun YS, Chen YM, Smales RJ, et al. Fracture resistance and microtensile bond strength of maxillary premolars restored with two resin composite inlay systems. Am J Dent. 2008;21:97–100.

    Google Scholar 

  13. Chu CH, Mei ML, Cheung C, Nalliah RP. Restoring proximal caries lesions conservatively with tunnel restorations. Clin Cosmet Investig Dent. 2013;5:43–50.

    Article  Google Scholar 

  14. Holberg C, Winterhalder P, Wichelhaus A, et al. Fracture risk of lithium-disilicate ceramic inlays: a finite element analysis. Dent Mater. 2013;29:1244–50.

    Article  Google Scholar 

  15. Xie KX, Wang XY, Gao XJ, Yuan CY, Li JX, Chu CH. Fracture resistance of root filled premolar teeth restored with direct composite resin with or without cusp coverage. Int Endod J. 2012;45:524–9.

    Article  Google Scholar 

  16. Saridag S, Sevimay M, Pekkan G. Fracture resistance of teeth restored with all-ceramic inlays and onlays: an in vitro study. Oper Dent. 2013;38:626–34.

    Article  Google Scholar 

  17. Suyama Y, Luhrs AK, De Munck J, et al. Potential smear layer interference with bonding of self-etching adhesives to dentin. J Adhes Dent. 2013;15:317–24.

    Google Scholar 

  18. Ausiello P, Apicella A, Davidson CL. Effect of adhesive layer properties on stress distribution in composite restorations–a 3D finite element analysis. Dent Mater. 2002;18:295–303.

    Article  Google Scholar 

  19. Ausiello P, Rengo S, Davidson CL, et al. Stress distributions in adhesively cemented ceramic and resin-composite Class II inlay restorations: a 3D-FEA study. Dent Mater. 2004;20:862–72.

    Article  Google Scholar 

  20. Lin CL, Chang CH, Ko CC. Multifactorial analysis of an MOD restored human premolar using auto-mesh finite element approach. J Oral Rehabil. 2001;28:576–85.

    Article  Google Scholar 

  21. Couegnat G, Fok SL, Cooper JE, et al. Structural optimization of dental restorations using the principle of adaptive growth. Dent Mater. 2006;22:3–12.

    Article  Google Scholar 

  22. Costa A, Xavier T, Noritomi P, Saavedra G, Borges A. The Influence of elastic modulus of inlay materials on stress distribution and fracture of premolars. Oper Dent. 2014;39:E160–70.

    Article  Google Scholar 

  23. Dejak B, Mlotkowski A. Three-dimensional finite element analysis of strength and adhesion of composite resin versus ceramic inlays in molars. J Prosthet Dent. 2008;99:131–40.

    Article  Google Scholar 

  24. Fennis WM, Kuijs RH, Kreulen CM, et al. A survey of cusp fractures in a population of general dental practices. Int J Prosthodont. 2002;15:559–63.

    Google Scholar 

  25. Nelson SJ. Wheeler’s dental anatomy. Physiology and Occlusion: Saunders; 2010.

    Google Scholar 

  26. Schroeder H. The periodontium. Berlin: Springer-Verlag; 1986. p. 185.

    Book  Google Scholar 

  27. Hagberg C. Electromyography and bite force studies of muscular function and dysfunction in masticatory muscles. Swed Dent J Suppl. 1986;37:1–64.

    Google Scholar 

  28. Berger T. Rate-distortion theory. Encycl Telecommun. 2003. doi:10.1002/0471219282.eot142.

    Google Scholar 

  29. Shillingburg HT, Hobo S, Whitsett LD, Jacobi R, Brackett SE. Fundamentals of fixed prosthodontics. Hanover Park: Quintessence Publishing, Quintessence Publishing Co; 1997.

    Google Scholar 

  30. Al-Omiri MK, Rayyan MR, Abu-Hammad O. Stress analysis of endodontically treated teeth restored with post-retained crowns: a finite element analysis study. J Am Dent Assoc. 2011;142:289–300.

    Article  Google Scholar 

  31. Castano MC, Zapata U, Pedroza A, et al. Creation of a three-dimensional model of the mandible and the TMJ in vivo by means of the finite element method. Int J Comput Dent. 2002;5:87–99.

    Google Scholar 

  32. Shimizu Y, Usui K, Araki K, et al. Study of finite element modeling from CT images. Dent Mater J. 2005;24:447–55.

    Article  Google Scholar 

  33. Hatamleh MM, Rodrigues FP, Silikas N, et al. 3D-FE analysis of soft liner-acrylic interfaces under shear loading. Dent Mater. 2011;27:445–54.

    Article  Google Scholar 

  34. Abuelenain DA, Ajaj RJ, El-Bab EI, et al. Comparison of stresses generated within the supporting structures of mandibular second molars restored with different crown materials: 3-D Finite Element Analysis (FEA). J Prosthodont. 2015;24:484–93.

    Article  Google Scholar 

  35. Ausiello P, Apicellab A, Davidsonc CL, et al. 3D-finite element analyses of cusp movements in a human upper premolar, restored with adhesive resin-based composites. J Biomech. 2001;34:1269–77.

    Article  Google Scholar 

  36. Fennis WM, Kuijs RH, Kreulen CM, et al. Fatigue resistance of teeth restored with cuspal-coverage composite restorations. Int J Prosthodont. 2004;17:313–7.

    Google Scholar 

  37. Ausiello P, Franciosa P, Martorelli M, et al. Numerical fatigue 3D-FE modeling of indirect composite-restored posterior teeth. Dent Mater. 2011;27:423–30.

    Article  Google Scholar 

Download references

Authors’ contributions

MLM: principal investigator, designed the study, collected data, performed statistical analyses and wrote the manuscript. YMC: designed the study. HL: consulted on mechanical engineering. CHC: supervised the work, evaluated the results and revised the manuscript for publication. All authors read and approved the final manuscript.

Competing interests

The authors declare that they have no competing interests.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Chun Hung Chu.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Mei, M.L., Chen, Y.M., Li, H. et al. Influence of the indirect restoration design on the fracture resistance: a finite element study. BioMed Eng OnLine 15, 3 (2016). https://doi.org/10.1186/s12938-015-0115-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12938-015-0115-4

Keywords