Table 2 A decade of literature on the utilization of the EStim system and their comprehensive parameters

From: Bioelectricity in dental medicine: a narrative review

Tissue or cell

Electrical Type

Intensity

Pulse

Frequency

Duration

Pulse width

Wave form

Outcomes

Refs.

Rat (L3 and L4 dorsal root ganglions)

Current stimulation (DC)

4 V/cm

Yes

Unmentioned

20 min/day; last for 56 days

500 μs

Square

Accelerated femoral osteoporotic fracture healing

[157]

Sheep (pelvic limb)

Current stimulation (AC)

1500 μA

yes

60 kHz

12 h/day, last for 30 days

40 ms

Unmentioned

Accelerated fracture healing

[199]

Sheep (dental implant–bone interface)

Current stimulation (DC)

7.5 μA

No

6 h/day, last for 84 days

No detectable improvement

[200]

Human (mesenchymal stem cells)

Capacitive coupling

1–2 V/cm

No

Continuous stimulation, last for 14 days

Osteogenic differentiation and increased calcium deposition

[194]

Rat (hindlimb skeletal muscle)

Current stimulation

1.5 V

Yes

40 Hz

60 min/day, 5 days/week, last for 28 days

Unmentioned

Unmentioned

Reduced muscle atrophy

[201]

Human (chondrocytes)

Capacitive coupling

2–3.5 V/cm

Yes

1 kHz

45 min × 3 times /day, last for 7 days

Unmentioned

Unmentioned

Increased genes expressions of collagen type II and aggrecan

[202]

Human (calvarial osteoblasts)

Capacitive coupling

20 mV/cm

Yes

60 kHz

1 h

Unmentioned

Unmentioned

Increased genes expressions of bone morphogenetic proteins (BMP)-2 and -4, TGF-β1,—β2 and -β3, fibroblast growth factor (FGF)-2, osteocalcin (BGP) and alkaline phosphatase (ALP)

[203]

Human (mesenchymal stem cells)

Current stimulation (DC)

1 V/cm

No

10 min/day, last for 14 days

Early osteogenesis in hMSCs; increased reactive oxygen species

[198]

Current stimulation (AC)

1 V/cm

Yes

10 Hz

10 min/day, last for 14 days

100 ms

Square

Late osteogenesis

Mouse (bone marrow-derived macrophages)

Current stimulation (AC)

0.5 V

Yes

500 Hz

6 h/day, last for 3 days

Unmentioned

Square

M1 polarization

[197]

Current stimulation (AC)

0.5 V

Yes

500 Hz

6 h/day, last for 3 days

Unmentioned

Sinusoidal

M2 polarization

Human (chondrocytes)

Current stimulation (DC)

1.5 V

No

1.5 h/day

Early late osteogenesis

[167]

Human (dermal fibroblasts)

Capacitive coupling

54 V/cm

Yes

60 Hz

2 h/day

100 μs

Unmentioned

Increased proliferation and migration

[175]

Human (keratinocytes)

Capacitive coupling

54 V/cm

Yes

60 Hz

2 h/day

100 μs

Unmentioned

Increased proliferation and migration

Mouse (skin wound)

Capacitive coupling

54 V/cm

Yes

60 Hz

2 h/day

100 μs

Unmentioned

Accelerated wound healing

Mouse

Inductive coupling (PEMF)

146.7 Gauss

Yes

75 Hz

Continuous stimulation, last for 5 days

Unmentioned

inhibition of inflammatory cytokines

[192]

Human (teared supraspinatus tendon)

Inductive coupling (PEMF)

25 Gauss

Yes

50 Hz

25 min/day, 5 days/week, last for 14 days

Unmentioned

Unmentioned

No detectable improvement

[204]

Mouse (swelled paws)

Inductive coupling (PEMF)

145 Gauss

Yes

10 Hz

Continuous stimulation, last for 32 days

Unmentioned

Unmentioned

Reduced local inflammatory cytokines and bone destruction

[193]

Rat (osteochondral defect)

Inductive coupling (PEMF)

Unmentioned

Yes

Unmentioned

3 h/day, last for 14 days

Unmentioned

Unmentioned

Chondrogenesis and cell hypertrophy via ERK and p38 MAPK pathways

[205]

Mouse (melanoma B16F10)

Inductive coupling (PEMF)

400 A

Yes

80 Hz

Unmentioned

Unmentioned

Unmentioned

Electroporation; Enhanced uptake of platinum

[206]

Rat (cardiac tissues)

Current stimulation (AC)

5 V

Yes

1 Hz

1 h/day, last for 3 days

10 μs

Square

Increased oxygen consumption and membrane permeability; Decreased contraction frequencies

[196]

Human (mesenchymal stem cells)

Capacitive coupling

1 V/cm

Unmentioned

Unmentioned

2 h/day, last for 21 days

Unmentioned

Unmentioned

Osteogenesis

[207]

Human (palatal wound)

Current stimulation (AC)

100 μA

Yes

9 kHz

30 s/day, last for 3 days

Unmentioned

Unmentioned

Positive effect on early wound closure; reduced inflammatory cytokines

[208]

Mouse (skin wound)

Capacitive coupling

53 V/m

Yes

Unmentioned

Continuous stimulation, last for 12 days

Unmentioned

Unmentioned

Reduced scarring, enhanced collagen synthesis; increased angiogenesis

[195]