Table 6 The evaluation time of the M\(^2\)IQA method and the MOS on different datasets

From: Deep learning-driven multi-view multi-task image quality assessment method for chest CT image

 

Dataset

Additional test set

LungCT-Diagnosis

CMB-LCA

M\(^2\)IQA

MOS

M\(^2\)IQA

MOS

M\(^2\)IQA

MOS

 

Tracheal carina

0.00 ± 0.00

4.19 ± 1.24

0.00 ± 0.00

5.97 ± 1.61

0.00 ± 0.00

6.16 ± 1.16

 

Bronchial beam

14.67 ± 1.78

30.21 ± 3.68

3.77 ± 0.91

10.45 ± 2.21

5.21 ± 1.68

8.84 ± 2.60

 

Rib

6.75 ± 0.95

25.95 ± 4.00

1.79 ± 0.41

21.02 ± 5.78

2.52 ± 0.87

17.15 ± 2.68

 

Arms position

0.04 ± 0.03

0.93 ± 0.24

N/A

N/A

N/A

N/A

Evaluation time (s)

(avg ± std)

Scan baseline position

0.14 ± 0.15

1.36 ± 0.40

N/A

N/A

N/A

N/A

 

Body position

0.01 ± 0.00

3.64 ± 0.93

0.01 ± 0.00

4.36 ± 1.09

0.01 ± 0.00

5.05 ± 0.97

 

Radiation protection

0.03 ± 0.03

1.01 ± 0.31

N/A

N/A

N/A

N/A

 

Artifact

1.59 ± 0.78

6.08 ± 2.95

2.10 ± 1.11

6.91 ± 2.77

2.74 ± 1.19

7.57 ± 3.93

 

Total

23.02 ± 2.86

70.07 ± 9.07

7.67 ± 2.15

48.72 ± 9.44

10.48 ± 3.29

44.78 ± 6.39