Table 1 Comparison of the mean wall displacements calculated by the FSI simulations and measured under constant flow rate conditions

From: Integrated particle image velocimetry and fluid–structure interaction analysis for patient-specific abdominal aortic aneurysm studies

Flow rate

(L/min)

Mean δexperimental

(mm)

Mean δFSI

(mm)

Relative difference with respect to δ experimental

(%)

4.9

0.34

0.30

− 12.29

6.7

0.51

0.51

− 0.39

9.1

0.72

0.89

22.37

11.6

1.11

1.41

27.27