Table 4 The ICC and 95% confidence interval (CI) for the comparison of all 12 IVUS quantitative measurement parameters between model segmentations and manual measurements

From: Comparison of deep learning-based image segmentation methods for intravascular ultrasound on retrospective and large image cohort study

Parameter types

Parameters

ICC

95% CI

Lumen

MinLD

0.955

(0.938–0.968)

MaxLD

0.969

(0.953–0.980)

LEI

0.683

(0.641–0.719)

Lumen-CSA

0.983

(0.979–0.985)

EEM

MinEEMD

0.961

(0.932–0.980)

MaxEEMD

0.967

(0.934–0.986)

EEM-CSA

0.986

(0.983–0.989)

Plaques

MinPT

0.539

(0.428–0.669)

MaxPT

0.784

(0.723–0.840)

PEI

0.532

(0.459–0.607)

PCSA

0.951

(0.943–0.957)

PB

0.955

(0.948–0.961)

  1. MinLD minimum lumen diameter, MaxLD maximum lumen diameter, LEI lumen eccentricity index, Lumen-CSA lumen cross-sectional area, MinEEMD minimum EEM diameter, MaxEEMD maximum EEM diameter, EEM-CSA EEM cross-sectional area, MinPT minimum plaque thickness, MaxPT maximum plaque thickness, PEI plaque eccentricity index, PCSA plaque cross-sectional area, PB plaque burden