Skip to main content

Table 2 Maximum of equivalent stress and strain results for different numbers of conic parts with a 1N pulling force

From: Finite element analysis of biomechanical interactions of a subcutaneous suspension suture and human face soft-tissue: a cadaver study

Model

2-cone

3-cone

4-cone

SEQV.(Pa)

662,340

448,324

235,490

EPTOEQV

1.57

1.42

1.24