From: Three-dimensional finite element analysis of the effect of alveolar cleft bone graft on the maxillofacial biomechanical stabilities of unilateral complete cleft lip and palate

Fig. 3

Mean and maximum EQV strain distributions of UCCLP maxillofacial bone sutures. Mean (a) and maximum (b) EQV strain distributions of maxillofacial bone sutures in non-bone graft model and models with bone graft in different sites of the alveolar cleft under occlusion of the center (1), the cleft side (2), the non-cleft side (3) and the anterior teeth (4)