Skip to main content

Table 4 Patient auditory behavior before and after electrodes dynamic range readjusting

From: Measuring implanted patient response to tone pips

Case

1

2

3

4

ECR1

ECR1

ECR2

ECR1

ECR2

ECR1

ECR2

CI use time

6 years, 8 months

5 months

7 months

4 months

8 months

2 years, 4 months

2 years, 10 months

Voice development

Clear and quasi-normal

Babbling

Increased babbling

Babbling

Words production with pronunciation errors

Increased babbling and words production

Poor acquisition of speech and words pronunciation

Favorable evolution in phrases comprehension and production

Conversation abilities

Sustained conversation without difficulty one meter away from speaker

Not reported

Not reported

Responds to his name at short distance or spoken loudly

Increasing word production

Communicates by shouting

Asks for repetition of words frequently

Sound detection

Can hear whispering

Ling sounds at high volume. Some domestic sounds

Most domestic sounds

Most domestic sounds

Low-intensity domestic sounds

Most domestic sounds

Words, sentences, and Ling sounds

Auditory behavior

Noisy environment tolerance

Discomfort to intense sounds

Inconsistent, lacking repetitive-ness, and discomfort to intense sounds

Gradually it became consistent

Not reported

Mild discomfort to shouting and vehicles noise

Removes the CI antenna by himself with intense sounds

Facial nerve stimulation without any discomfort

Stopped removing the CI antenna by himself