From: Hydraulic conductivity and low-density lipoprotein transport of the venous graft wall in an arterial bypass

Fig. 5

Numerical results of cw (normalized by c0) along different lines for cases with stenosis degrees of 70%, 80% and 90%. a Distribution of cw in the venous graft. b Percentage difference of cw in the venous graft. The percentage difference was defined as (cw, 80% occluded − cw, 70% occluded)/cw, 70% occluded or (cw, 90% occluded − cw, 70% occluded)/cw, 70% occluded