Skip to main content

Table 8 Classification results of net 3 according to different feature selection methods

From: A novel intensity-based multi-level classification approach for coronary plaque characterization in intravascular ultrasound images

Selection method

Sensitivity (%)

Specificity (%)

Accuracy (%)

AUC

w/o selection

80.4

75.2

76.7

0.778

GA

80.2

75.8

76.6

0.780

PCA

80.6

75.9

77.2

0.783