From: Mathematically modeling fluid flow and fluid shear stress in the canaliculi of a loaded osteon

Fig. 3

Fluid flow rate amplitude (\(\left| Q \right|\), FFRA) and fluid shear stress amplitude (\(\left| \tau_w \right|\), FSSA) as a function of the loading amplitude (ε z0) and frequency (ω) at R = 5 × 10−7 m and k = 10-18 m2. a Fluid flow rate amplitude as a function of the loading amplitude. b Fluid shear stress amplitude as a function of the loading amplitude. c Fluid flow rate amplitude as a function of the frequency. d Fluid shear stress amplitude as a function of the frequency