Skip to main content

Table 3 Comparison of flow rates between the CFD simulation and the previous in vitro experiment

From: The role of the circle of Willis in internal carotid artery stenosis and anatomical variations: a computational study based on a patient-specific three-dimensional model

 

Flow rates in the CoW without stenosis

Flow rates in the CoW with 50 % RICA stenosis

Experiment (ml/s)

CFD (ml/s)

Percentage difference (%)

Experiment (ml/s)

CFD (ml/s)

Percentage difference (%)

R-ACA

1.34

1.33

−1.17

1.22

1.19

−2.21

R-MCA

3.26

3.21

−1.41

3.06

2.93

−4.18

R-PCA

1.73

1.83

5.85

1.59

1.70

6.67

L-PCA

1.72

1.83

6.56

1.56

1.70

8.78

L-MCA

3.26

3.21

−1.41

2.75

2.64

−3.96

L-ACA

1.34

1.33

−1.17

1.18

1.25

5.59

Total flow rate

12.65

12.74

0.72

11.36

11.41

0.40