Skip to main content

Table 3 The Yeoh SEF coefficients generated to develop the material models used to represent the experimental data that characterise the mechanical response of aortic plaque tissue generated by Loree et al. (1994) [2].

From: Simulation of human atherosclerotic femoral plaque tissue: the influence of plaque material model on numerical results

Group

C10 (MPa)

C20 (MPa)

C30 (MPa)

R2

Calcified

1.41E-03

4.73E+00

8.51E-01

0.99825

Cellular

4.84E-03

3.59E-01

6.08E-01

0.99953

Hypocellular

2.20E-01

5.09E-01

6.19E-01

0.99903

  1. The R2 values denote the quality of the fit of each set of coefficients to the corresponding average curve used to represent the experimental data.