Table 3 Calculated inlet pressure, outlet pressure and mass flow rate

From: Computational fluid dynamics simulation of airflow in the trachea and main bronchi for the subjects with left pulmonary artery sling

Subject Inlet pressure (Pa) Outlet cross-sectional area (mm 2) Outlet minimum cross-sectional area (mm 2) Outlet mass flow rate × 10 6(kg/s)* Outlet flow velocity (m/s)
   Left Right Left Right Left Right Left Right
A(H) 0.68 24.26 27.70 24.26 27.70 −71.54 −81.59 2.52 2.65
B 475.98 4.30 7.19 4.30 4.26 −44.31 −73.62 8.81 8.61
C 282.81 5.17 5.50 2.72 5.43 −51.04 −102.02 8.43 15.32
D 78.90 15.73 26.49 15.73 18.09 −118.51 −19.32 6.39 1.46
E 914.50 13.63 15.74 13.63 15.74 −216.03 66.32 14.14 3.44
  1. *For mass flow rate, minus means flow-out and positive is flow-in.