From: Monte Carlo simulation of laser beams interaction with the human eye using Geant4
Structure | Absorption coefficient (μ a) | Reduced scattering coefficient ( ) | RINDEX | ABSLENGTH | RAYLEIGH |
---|---|---|---|---|---|
Air | - | - | 1.000 [29] | - | - |
Sclera | 0.25 mm-1 [26] | 8.00 mm-1 [26] | 1.47 [30] | 4.0 mm | 0.1250 mm |
Cornea | - | - | 1.376 [29] | - | - |
Aqueous humor | - | - | 1.336 [29] | - | - |
Iris | - | - | - | - | - |
Crystalline lens | - | - | 1.405 [29] | - | - |
Vitreous humor | - | - | 1.337 [29] | - | - |
ILM | 0.25 mm-1 [26] | 0.75 mm-1 [26] | 1.337(*b) | 4.0 mm | 1.333 mm |
NR(*a) | 0.25 mm-1 [26] | 0.75 mm-1 [26] | 1.337(*b) | 4.0 mm | 1.333 mm |
RPE | 90.00 mm-1 [26] | 19.20 mm-1 [26] | 1.337(*b) | 0.0111 mm | 0.0521 mm |
Druse | 12.6 cm-1 [31] | 412 cm-1 [31] | 1.337(*b) | 0.7936 mm | 0.0243 mm |
Choroid | 8.00 mm-1 [26] | 3.60 mm-1 [26] | 1.337(*b) | 0.1250 mm | 0.2778 mm |