Skip to main content

Table 4 Some published model data adopted by previous researchers in their human systemic arterial models

From: Review of Zero-D and 1-D Models of Blood Flow in the Cardiovascular System

Source Model Model parameters
Cavalcanti and Belardinelli [98] RCR Original values:
R c = 52 dyn · s/cm5, R = 1200 dyn · s/cm5, C = 0.001 cm5/dyn
Converted into physiological units:
R c = 0.039 mmHg s/ml, R = 0.09 mmHg s/ml, C = 1.333 ml/mmHg
Cole et al. [165] RC R = 0.7 mmHg s/ml, C = 3.1 ml/mmHg,
Cole et al. [165] RCR R c = 0.03 mmHg s/ml, R = 0.7 mmHg s/ml, C = 3.1 ml/mmHg
Cole et al. [165] RLCR1 R c = 0.028 mmHg s/ml, R = 0.65 mmHg s/ml, C = 2.8 ml/mmHg, L = 0.0018 mmHg/(ml s)
Cole et al. [165] RLCR2 R c = 0.045 mmHg s/ml, R = 0.63 mmHg s/ml, C = 2.53 ml/mmHg, L = 0.0054 mmHg/(ml s)
Lerma et al. [166] RCR Original values:
R c = 57 dyn · s/cm5, R = 1332 dyn · s/cm5, C = 0.0007 cm5/dyn
Converted into physiological units:
R c = 0.043 mmHg s/ml, R = 1 mmHg s/ml, C = 0.9332 ml/mmHg
Segers et al. [167] RCR R c = 0.124 mmHg s/ml, R = 1.28 mmHg s/ml, C = 1.01 ml/mmHg