Skip to main content

Table 1 Parameter values for TMP simulation

From: High-frequency irreversible electroporation (H-FIRE) for non-thermal ablation without muscle contraction

Quantity Parameter Value Units Reference
Conductivity σ e 1.2 S m-1 [50]
  σ pm 3 × 10-7   [51]
  σ c 0.3   [52]
  σ ne 3 × 10-7   set equal to σ pm
  σ n 0.3   set equal to σ c
Permittivity ε e 6.4 × 10-10 A s V-1 m-1 [53]
  ε pm 4.4 × 10-11   [51]
  ε c 6.4 × 10-10   [53]
  ε ne 4.4 × 10-11   set equal to ε pm
  ε n 6.4 × 10-10   [53]
Radius R c 7.5 × 10-6 m estimated from [54]
  R n 5 × 10-6   estimated from [54]
Thickness d pm 5 × 10-9 m [55]
  d ne 5 × 10-9   set equal to [55]