Skip to main content

Effects of different running intensities on the micro-level failure strain of rat femoral cortical bone structures: a finite element investigation

Abstract

Background

Running with the appropriate intensity may produce a positive influence on the mechanical properties of cortical bone structure. However, few studies have discussed the effects of different running intensities on the mechanical properties at different levels, especially at the micro-level, because the micromechanical parameters are difficult to measure experimentally.

Methods

An approach that combines finite element analysis and experimental data was proposed to predict a micromechanical parameter in the rat femoral cortical bone structure, namely, the micro-level failure strain. Based on the previous three-point bending experimental information, fracture simulations were performed on the femur finite element models to predict their failure process under the same bending load, and the micro-level failure strains in tension and compression of these models were back-calculated by fitting the experimental load–displacement curves. Then, the effects of different running intensities on the micro-level failure strain of rat femoral cortical bone structure were investigated.

Results

The micro-level failure strains of the cortical bone structures expressed statistical variations under different running intensities, which indicated that different mechanical stimuli of running had significant influences on the micromechanical properties. The greatest failure strain occurred in the cortical bone structure under low-intensity running, and the lowest failure strain occurred in the structure under high-intensity running.

Conclusions

Moderate and low-intensity running were effective in enhancing the micromechanical properties, whereas high-intensity running led to the weakening of the micromechanical properties of cortical bone. Based on these, the changing trends in the micromechanical properties were exhibited, and the effects of different running intensities on the fracture performance of rat cortical bone structures could be discussed in combination with the known mechanical parameters at the macro- and nano-levels, which provided the theoretical basis for reducing fracture incidence through running exercise.

Background

Cortical bone bears most of the external loads, and once damage occurs in the cortical bone structure, cracks will propagate under different loads and eventually lead to fracture [1, 2]. The inevitable degeneration in the mechanical properties of cortical bone with age will further increase the incidence of fracture [3]. Therefore, exploring an appropriate method to improve the mechanical properties to reduce fracture incidence is important in the research field of biomechanics.

Running exercise is recognized as an effective way to improve bone mechanical properties, and running with the appropriate intensity could increase bone density and strength [4, 5]. Several experiments considered that the fracture load, cortical bone thickness, and tissue-level elastic modulus in the rat femoral and tibial cortical bone structures significantly increased under treadmill running at low or moderate intensity [6,7,8]. However, different viewpoints exist in the studies on the effects of high-intensity running on the mechanical properties of cortical bone. Several studies found that the rat femoral cortical bone under high-intensity running was inferior to that of the sedentary group in terms of apparent mechanical properties and microstructural morphological parameters [9, 10]. Moreover, a report suggested that high-intensity running increased cortical bone density and thickness but not ultimate strength [11]. Therefore, the effects of different running intensities on the mechanical properties of cortical bone structure remain to be further investigated.

Furthermore, comparisons of several experimental results found different changing trends in the mechanical parameters at the macro-, micro-, and nano-levels even under the same running intensity. For example, the mechanical stimuli of running did not change the tissue-level elastic modulus and hardness but improved the microstructural morphology [12]. The main reason for this phenomenon is that cortical bone is hierarchical with its overall mechanical response being influenced by the interplay of its structure and material composition at different levels [13, 14]. Thus, mastering the changes in mechanical parameters at different levels is necessary to investigate the effects of different running intensities on the mechanical properties of cortical bone. Current experiments can obtain the macro- and nano-levels mechanical parameters but have difficulties in measuring the micro-level mechanical parameters in cortical bone structure [15, 16]. Most studies only reported the changes in the microstructural morphology parameters under different loading environments [6, 12]. The effects of micromechanical parameters on cortical bone fracture performance are significant, especially for micro-level failure strain in the osteon [17]. The softening and fracture time of bone structure are partly determined by the micro-level failure strain, and the processes of bone resorption and formation are also influenced by the micro-level failure strain [18, 19]. These illustrate that micromechanical properties are of great importance in the mechanics and physiology of cortical bone structure. Therefore, accurate acquisition of micromechanical parameters is a prerequisite for mastering fracture performance and predicting fracture risk in cortical bone structure.

The purpose of this paper was to propose an approach that combines finite element (FE) analysis and experimental data to predict the micro-level failure strain for the rat femoral cortical bone structures. FE analyses were performed on the rat femoral cortical bone structures to simulate their failure processes under three-point bending load. Different failure strains were repeatedly assigned to the FE models during simulation, and the suitable values could be back-calculated by fitting the load–displacement curves between the experiments and simulations. Then, the effects of different running intensities on the micro-level failure strain in the cortical bone structures were investigated, which provided the theoretical basis for reducing fracture incidence through running exercise.

Results

Prediction results of micro-level failure strain

Fracture simulations were performed on the forty-eight femoral FE models to predict the tensile and compressive micro-level failure strains of cortical bone structures in the different rat groups. All the material input parameters, except the failure strain, have been measured in the previous experiments; therefore, the fitting accuracy in the load–displacement curves depended on the assignment of the failure strain. The adjustment interval of the tensile failure strain was set to 0.001 to ensure the simulation precision. That was, each simulation was conducted by adding 0.001 to the last tensile strain and then re-running the fracture simulation until the fit was successful. Figure 1 shows the comparison of the prediction precision with different tensile failure strains. A complete fracture occurred later as tensile failure strain increased, resulting in an increase in fracture load. The discrepancies in the load–displacement curves were not remarkable and the differences in the fracture parameters between every two curves were less than 5% when the adjustment interval of the tensile failure strain was set to 0.001. Therefore, this comparison indicated that setting the tensile strain adjustment interval to 0.001 was reasonable when performing fitting.

Fig. 1
figure 1

Comparison of the prediction precision with different tensile failure strains

The fitting process was completed when the differences in the fracture parameters between the experiment and simulation were less than 5%, and the predicted tensile and compressive failure strains in the FE models were the micro-level failure strains of the cortical bone structure. The predicted micro-level failure strains in the different groups are shown in Table 1. Significant differences in micro-level failure strain were detected in the rat cortical bone structures under treadmill running with different intensities, which indicated that the different mechanical stimuli of running had a significant influence on the micromechanical properties. The greatest failure strain occurred in the cortical bone structure under low-intensity treadmill running, and the lowest failure strain occurred under high-intensity treadmill running.

Table 1 The predicted micro-level failure strains of cortical bone structures in different groups, mean ± SD

Moreover, the load–displacement curves of the two femur FE models and the corresponding cortical bone samples were selected from each group for observation, as shown in Fig. 2. Meanwhile, Table 2 shows the apparent stiffness and fracture load of the samples in the previous experiment. Because the input material parameters and the femur micro-CT images were both obtained from previous experiments, the established femur FE models should be similar to the experimental cortical bone samples. Thus, the simulated and experimental load–displacement curves could be well fitted, and the fracture parameters between the experiments and simulations were nearly the same. The comparison of the curves showed that quasi-brittle fracture occurred in the three-point bending experiment and simulation, which indicated that the structure experienced a long elastic stage and then entered the fracture stage. Thus, the micro-level failure strain could be back-calculated directly from fitting the load–displacement curves because the yield stage was not obvious.

Fig. 2
figure 2

The load–displacement curves obtained from the experiment and simulation in each rat group. a SED group; b EX12 group; c EX16 group; d EX20 group

Table 2 The fracture parameters of the femur samples measured in the previous experiment, mean ± SD

The microarchitecture parameters in the rat femoral cortical bone

The microarchitecture parameters of the rat femoral cortical bone structures were calculated with CTAn, as shown in Table 3. Statistically greater Ct.BMD was detected in the EX12 group compared with the SED and EX16 groups (p < 0.05). Statistically greater Ct.Th was detected in the EX12 group compared with the SED and EX20 groups (p < 0.05). Significantly greater Ct.P was detected in the EX16 group compared with the SED and EX12 groups (p < 0.05).

Table 3 Microarchitecture parameters of the femoral cortical bone evaluated by micro-CT, mean ± SD

Discussion

The cortical bone structure may express different changing magnitudes and trends in the mechanical properties at different levels even under the same load owing to its hierarchical structural characteristic [20]. Therefore, mastering the mechanical parameters at the macro- and micro-levels is necessary to investigate the effects of different loading conditions on the fracture performance of cortical bone structure. Micromechanical parameters are difficult to measure experimentally because of the limitations in the structural characteristics. Thus, this study aimed to propose an approach to predict a micro-level mechanical parameter in the cortical bone structure and observe the changes in this mechanical parameter under running with different intensities.

One of the advantages of FE analysis is that the mechanical state in the FE model can be observed at any time [21]. Figure 3 exhibits the complete failure process in the femur FE model under three-point bending load. At the initial loading stage, the principal strain was high at the loading and constraint locations in the femur, and few green damaged elements first appeared near the upper indenter, as shown in Fig. 3a. Then, a large number of green damaged elements appeared at the lower middle of the femoral shaft with bending, which was opposed to the upper indenter, as shown in Fig. 3b. When the bending reached a certain degree, the red failed elements appeared at the lower side of the cortical bone structure and expanded longitudinally from the middle to both sides, forming a fan-shaped failure region, as shown in Fig. 3c. In addition, because the principle strain increased more quickly at both sides of the lower cylinders due to the support during bending, the elements near the lower cylinders occurred failure at the middle loading stage. However, no more new damaged elements occurred, which illustrated that the crack in the femur under bending load propagated in the middle position but not in the constraint location. When the red failed elements in the lower part of the cortical bone extended to both sides to a certain degree, they extended transversely and upward instead of longitudinally along the femur until the failed elements penetrated the central section of the femoral shaft, resulting in complete fracture, as shown in Fig. 3d. The comparison stated that the fracture pattern in the simulation was consistent with the previous experimental result, as shown in Fig. 3e [22]. Furthermore, the femur fracture under three-point bending load has been reported to be caused by the continuous propagation of the lower surface crack in transverse and longitudinal directions, which cuts off the central section of the femoral shaft [23]. These comparisons could verify the feasibility and accuracy of the simulation in this study.

Fig. 3
figure 3

The failure process in the FE model under three-point bending load and the comparison of the fracture patterns between the present simulation and the previous experiment. The “SDV1” represents the damage variable D. a initial loading stage; b element damage stage; c element failure stage; d structure fracture stage; e experimental fracture pattern

The results showed that the micro-level failure strains of cortical bone structure in the four rat groups were statistically different from each other (p < 0.05), which indicated that different mechanical stimuli of running produced significant effects on the micromechanical properties of cortical bone structure. The EX12 group generated the greatest improvement in the micro-level failure strain, and the failure strain in the EX20 group was significantly lower than that in the SED group. The micro-level failure strain represents the failure threshold in the osteon, so its value could be used to describe the micromechanical properties of the structure and partly determine the apparent fracture process [24, 25]. Thus, this finding suggested that moderate and low-intensity running were effective in enhancing the micromechanical properties, whereas high-intensity running led to the weakening of the micromechanical properties of cortical bone structure.

A comprehensive discussion of the mechanical parameters at different levels is necessary to investigate the effects of different running intensities on the fracture performance of cortical bone owing to its hierarchical structural organization. Previous experiment showed that the fracture load and apparent stiffness increased in the EX12 and EX16 groups compared with the SED group, as shown in Table 2. Macro-level mechanical parameters are often determined by the combination of mechanical parameters at the micro- and nano-levels and microstructural morphology [26, 27]. Thus, the fracture load should be determined by a combination of microarchitecture parameters, micro-level failure strain, and tissue-level elastic modulus. The statistical results of the microarchitecture parameters in this study showed that the Ct.Th in the EX12 and EX16 groups was statistically greater than those in the SED and EX20 groups, and the EX16 group had a remarkably greater Ct.P compared with the EX12 group. Moreover, the tissue-level elastic modulus is significantly greater in the EX12 and EX16 groups than in the other two groups, as shown in Table 4. The differences in the predicted micro-level failure strains suggested that the micro- and nano-levels mechanical properties in the EX12 and EX16 groups were better than those in the other two groups, and their mechanical properties at the macro-level, including fracture load and apparent stiffness, were better than those of the other two groups. Therefore, running at moderate and low intensities could improve the mechanical properties of cortical bone structure.

Table 4 The tissue-level elastic modulus of the cortical bone measured by nanoindentation test, mean ± SD

The previous experiment also showed that the fracture load was the lowest in the EX20 group, but the apparent stiffness was greater compared with the other groups, as shown in Table 2. This phenomenon states that different macro-level mechanical parameters in one cortical bone structure may also express different variations. The reason may be that the macro-level mechanical parameter was determined by different micro- and nano-levels parameters. No substantial differences in the microarchitecture parameters are found between the SED and EX20 groups in Table 3. Although the longitudinal elastic modulus in the EX20 group was significantly lower than that in the SED group, the femur fracture under three-point bending load was mainly caused by transverse deformation, which depended on the transverse elastic modulus [28]. No remarkable differences in the transverse elastic modulus existed between the EX20 and SED groups, suggesting that the differences in fracture performance between the EX20 and SED groups may be determined by the micromechanical properties. The simulation results showed that the micro-level failure strain in the EX20 group was substantially lower than those in the other groups, which led to advanced fracture and low fracture load. However, its apparent stiffness was not low because of the better microstructure morphology [29]. Therefore, the fracture load in the EX20 group was lower than that in the SED group mainly because of the decrease in micro-level failure strain.

Several limitations existed during the simulations in this study. First, the loading condition was single, only the three-point bending load was considered. In reality, the femur may be subjected to compression, torsion, and impact loads. Although this study only simulated the cortical bone fracture under three-point bending load, the established numerical method may also be applicable to bone fractures caused by other types of loads. Second, the microarchitecture features in the fracture surface have a great influence on the fracture performance. Our previous experiment did not conduct scanning electron microscopy analysis on the cortical bone fracture surface; hence, the microarchitecture features of the fracture surface could not be observed. However, the reasons for the changes in the macro-level mechanical parameters and the relationships between microarchitecture and micro-level failure strain under different mechanical stimuli were discussed, which may compensate for the inability to investigate the effects of the fracture surface on the microarchitecture features.

Conclusions

The failure process in the rat femur FE models under three-point bending load was simulated, and the micro-level failure strain was predicted by back-calculation with the experimental data. The micro-level failure strains of cortical bone structures in the four rat groups were statistically different from each other, which indicated that different mechanical stimuli of running produced significant effects on the micromechanical properties of cortical bone structure. The greatest micro-level failure strain occurred in the cortical bone structure under low-intensity running, and the lowest failure strain occurred in the structure under high-intensity running. This finding suggested that moderate and low-intensity running were effective in enhancing the micromechanical properties, whereas high-intensity running led to the weakening of the micromechanical properties of cortical bone structure.

Materials and methods

Description of the previous three-point bending experiment

The three-point bending experimental data needed in this study were obtained from our previous research, which focused on measuring the macro- and nano-levels mechanical parameters of the rat femoral cortical bone structures under treadmill running with different intensities [22]. In this experiment, five-month-old male Sprague–Dawley rats were regarded as the experimental objects. Forty-eight healthy rats were randomly assigned to the sedentary control group (SED, n = 12) and treadmill running groups with speeds of 12 m/min (EX12, n = 12), 16 m/min (EX16, n = 12), and 20 m/min (EX20, n = 12). Throughout the experimental period, the rats in the exercise groups ran on the treadmill for 30 min/day, 5 days a week, for 4 weeks. The rats in the sedentary control group were allowed to move freely in the cages. All the rats were killed, and their right femurs were harvested after one month of rearing.

The three-point bending experiment was performed on the femur samples to obtain the fracture load. The experimental span was set to 20 mm, and the indenter was loaded at a uniform speed of 0.5 mm/min downward. The bending load from the indenter was applied on the cortical bone structure in the middle of the femoral shaft. The nanoindentation test was performed on the cortical bone to measure the tissue-level elastic modulus. Two cortical bone structures with equal size were cut along the axis of the femoral shaft in each sample. One was used to measure the transverse elastic modulus, and the other measured the longitudinal elastic modulus. Nanoindentation tests were performed with a speed of 750 μN/s and an indentation depth of 1000 nm [22].

Micro‑CT scanning

Forty-eight femurs were scanned by a micro-CT system at 18 μm voxel image resolution with 70 kV, and 100 μA. The scanned data were reconstructed using the NRecon software. The region of interest (ROI) was manually selected for the analysis of the femoral micro-CT images with the CTAn software. The total 5 mm cortical bone structure from the middle of the femoral shaft to the proximal and distal ends was selected as the ROI, where the failure location in the femur under three-point bending load was also in the range of this region. The microstructural parameters in the ROI of the femoral shaft cortical bone structure, including the cortical bone mineral density (Ct.BMD), cortical bone thickness (Ct.Th), and cortical bone porosity (Ct.P), were measured.

Establishment of finite element models

The femoral micro images were imported into the MIMICS software to reconstruct the geometric model. Because the failure region was located at the cortical bone structure in the middle of the femoral shaft during three-point bending load, the trabecular bone structure was not created in the FE model. The image segmentation was chosen in the range of 800–2000 HU, and the trabecular bone region in the MIMICS software was not selected during the geometric reconstruction process [34]. Then, the femur FE model was established by ABAQUS software using the C3D8 element. The upper rigid indenter and lower rigid cylinders were created above and below the femur FE model to simulate the experiment boundary condition. Due to the large surface roughness of the lower cylinders in the electronic testing machine, great friction can be provided between the lower surfaces of the cylinders and the femur. Therefore, the lower cylinders were fixed to the lower surface of the FE model using the TIE connection. The upper indenter was set to frictionless contact with the femur model. The upper indenter was compressed vertically downward, and the two lower cylinders were fully constrained to implement bending load. The loading schematic diagrams in the previous experiment and the present simulation can be seen in Fig. 4.

Fig. 4
figure 4

The schematic diagrams of the boundary condition on the rat femur under three-point bending. a the experimental boundary condition; b the simulated boundary condition

Fracture simulation with finite element models

As observed in the previous experiment and literature, the quasi-brittle fracture occurred on the rat femoral cortical bone structure under three-point bending load [12, 22]. Therefore, the damage process can be described as the degradation of the structural mechanical properties when the critical failure strain in the element was reached [30]. This was accomplished using the ABAQUS User Material (UMAT) subroutine, where the material degradation was introduced to describe the progressive loss of stiffness due to crack initiation and propagation. In a quasi-static regime, the constitutive equation of elasticity introduced by a damage mechanics degradation can be expressed as [31, 32]:

$${\varvec{\upsigma}}={\mathbf{C}}_{\mathrm{d}} {\varvec{\upvarepsilon}}$$
(1)
$${\mathbf{C}}_{\mathrm{d}}=(1-\mathrm{D})\mathbf{C}$$
(2)

where σ is the element stress tensor, \({\mathbf{C}}_{\mathrm{d}}\) is the damaged stiffness matrix tensor in the element, ε is the element strain tensor, D is the damage variable, C is the initial stiffness matrix tensor in the element.

A key point in this fracture simulation is the choice of the damage evolution law describing the damage accumulation in the FE model. Because the bone failure process is mainly controlled by the element strain in the FE model, the damage evolution law was selected as [33]:

$$\mathrm{D}=0\mathrm{ for }(\upvarepsilon \le {\upvarepsilon }_{\mathrm{f}});\mathrm{ D}=1-{\mathrm{e}}^{\left(1-\frac{\upvarepsilon }{{\upvarepsilon }_{\mathrm{f}}}\right)}\mathrm{ for }(\upvarepsilon >{\upvarepsilon }_{\mathrm{f}})$$
(3)

where ε is the maximum or minimum principal strain in the element, εf is the critical tensile or compressive failure strain in the cortical bone material.

The structure remained in the elastic stage, and the initial stiffness matrix in the element was not degraded when the principal strain was less than the critical failure strain of the cortical bone material. The principal strain gradually exceeded the critical failure strain as the bending increased, and the structure entered into the damage stage. The damage variable D increased with the principal strain, causing a decrease in the element stiffness. The damaged stiffness matrix was adopted to update the stress and Jacobian matrix in the element. The Jacobian matrix after the onset of the damage could be described as expression (4) [34]. When the damage variable D approached 0.999, the element failed and lost its bearing capacity. With further bending, the cortical bone structure cannot be effectively loaded and underwent complete fracture when the failed element increased and accumulated to a certain degree.

$$\frac{\partial {\varvec{\upsigma}}}{\partial {\varvec{\upvarepsilon}}}={\mathbf{C}}_{\mathrm{d}}+\frac{\partial {\mathbf{C}}_{\mathrm{d}}}{\partial {\varvec{\upvarepsilon}}}: {\varvec{\upvarepsilon}}={\mathbf{C}}_{\mathrm{d}}+\frac{\partial {\mathbf{C}}_{\mathrm{d}}}{\partial \mathrm{D}}\times \frac{\partial \mathrm{D}}{\partial\upvarepsilon }$$
(4)

Prediction process of micro-level failure strain

In the simulation process, the maximum and minimum principal strains in the element were compared with the critical tensile or compressive failure strains of the cortical bone material to determine whether damage occurred. Therefore, cortical bone fracture can be simulated by inputting four material parameters in the UMAT subroutine, namely, the elastic modulus, Poisson’s ratio, and critical tensile and compressive failure strains. First, the longitudinal and transverse tissue-level elastic moduli of the corresponding rat femoral cortical bone samples have been measured by previous nanoindentation test, as shown in Table 4 [22]. The poisson's ratio was set to 0.3 [1, 14]. Additionally, the ratio of critical tensile to compressive failure strain of the cortical bone material was set to 0.6 according to the literature [35, 36]. Therefore, only one material input parameter, namely the critical tensile or compressive failure strain, was not known. The critical tensile or compressive failure strain in the cortical bone material was the micro-level failure strain in the structure, which was the predicted object in the paper.

The first step was to select the approximate range of micro-level failure strain for the rat cortical bone structure. According to the literature, the failure strain of the cortical bone material is in the range of 0.01–0.05 [37, 38]. Thus, the prediction started with tensile and compressive failure strains of 0.01 and 0.0167, respectively. Every FE model was solved with a range of failure strains in tension and compression while maintaining 0.6 asymmetry until a single set of values could be determined that could make the simulated load–displacement curve best fit the experimentally measured one. Thus, the micro-level failure strain could be predicted by back-calculated fitting from the experimental results. The flowchart of the prediction process can be seen in Fig. 5.

Fig. 5
figure 5

Flow chart of the prediction process for the micro-level failure strain

Mesh sensitivity analysis

Mesh sensitivity analysis was performed to determine the suitable element size for the femur FE model. Based on the femoral micro images from the SED group, different element sizes (20, 30, 40, 50, and 60 μm) were selected to establish the femur FE models. The load–displacement curves predicted in the simulations with the five FE models are shown in Fig. 6. The shape of the load–displacement curve was similar when the material input parameters were the same and only the element size was different. However, certain differences existed in the fracture load and fracture time. The FE model with coarse element underwent complete fracture early because the damage variable rose faster for the large element size, resulting in a faster decrease in the structural stiffness. The predicted three curves had no obvious differences in the fracture parameters when the element size was in the range of 30–50 μm. Therefore, the element size of the forty-eight femoral FE models established in this study was set at 30 μm considering the prediction accuracy.

Fig. 6
figure 6

Mesh sensitivity analysis for the finite element models with different mesh size

Statistical analysis

Data analysis was performed using SPSS software. The mean values of all the parameters in each group were calculated. Differences among all groups were analyzed by one-way analysis of variance. If significant differences were observed, the LSD post hoc test was used to compare the differences between every two groups. The significance level of p was chosen to be 0.05.

Availability of data and materials

The datasets used during the current study are available from the corresponding author on reasonable request.

Abbreviations

FE:

Finite element

References

  1. Li JW, Gong H. Fatigue behavior of cortical bone: a review. Acta Mech Sin. 2020;37(3):516–26.

    Article  Google Scholar 

  2. Bowman L, Loucks AB. In vivo assessment of cortical bone fragility. Curr Osteoporos Rep. 2020;18(1):13–22.

    Article  Google Scholar 

  3. Tarantino U, Rao C, Tempesta V, Gasbarra E, Feola M. Hip fractures in the elderly: the role of cortical bone. Injury. 2017;47(S4):107–11.

    Google Scholar 

  4. Tamakoshi K, Nishii Y, Minematsu A. Upward running is more beneficial than level surface or downslope running in reverting tibia bone degeneration in ovariectomized rats. J Musculoskel Neuron. 2018;18(4):493–500.

    Google Scholar 

  5. Berman AG, Hinton MJ, Wallace JM. Treadmill running and targeted tibial loading differentially improve bone mass in mice. Bone Rep. 2019;10: 100195.

    Article  Google Scholar 

  6. George D, Pallu S, Bourzac C, Wazzani R, Allena R, Remond Y, Portier H. Prediction of cortical bone thickness variations in the tibial diaphysis of running rats. Life Basel. 2022;12(2):233.

    Article  Google Scholar 

  7. Saers JPP, DeMars LJ, Stephens NB, Jashashvili T, Carlson KJ, Gordon AD, Shaw CN, Ryan TM, Stock JT. Combinations of trabecular and cortical bone properties distinguish various loading modalities between athletes and controls. AM J Phys Anthropol. 2021;174(3):434–50.

    Article  Google Scholar 

  8. Iwamoto J, Takeda T, Sato Y. Effect of treadmill exercise on bone mass in female rats. Exp Anim. 2005;54(1):1–6.

    Article  Google Scholar 

  9. Scott JM, Swallow EA, Metzger CE, Kohler R, Wallace JM, Stacy AJ, Allen MR, Gasier HG. Iron deficiency and high-intensity running interval training do not impact femoral or tibial bone in young female rats. Brit J Nutr. 2022;128(8):1518–25.

    Article  Google Scholar 

  10. Li Z, Liu SY, Xu L, Xu SY, Ni GX. Effects of treadmill running with different intensity on rat subchondral bone. Sci Rep. 2017;7:1977.

    Article  Google Scholar 

  11. Suominen TH, Korhonen MT, Alen M, Heinonen A, Mero A, Tormakangas T, Suominen H. Effects of a 20-week high-intensity strength and sprint training program on tibial bone structure and strength in middle-aged and older male sprint athletes: a randomized controlled trial. Osteoporosis Int. 2017;28(9):2663–73.

    Article  Google Scholar 

  12. Fang J, Gao JZ, Gong H, Zhang TL, Zhang R, Zhan BC. Multiscale experimental study on the effects of different weight-bearing levels during moderate treadmill exercise on bone quality in growing female rats. Biomed Eng Online. 2019;18:33.

    Article  Google Scholar 

  13. Milovanovic P, Rakocevic Z, Djonic D, Zivkovic V, Hahn M, Nikolic S, Amling M, Busse B, Djuric M. Nano-structural, compositional and micro-architectural signs of cortical bone fragility at the superolateral femoral neck in elderly hip fracture patients vs. healthy aged controls. Exp Gerontol. 2014;55:19–28.

    Article  Google Scholar 

  14. Fan RX, Liu J, Jia ZB. Biomechanical evaluation of different strain judging criteria on the prediction precision of cortical bone fracture simulation under compression. Front Bioeng Biotech. 2023;11:1168783.

    Article  Google Scholar 

  15. Chappard D, Basle MF, Legrand E, Audran M. New laboratory tools in the assessment of bone quality. Osteoporosis Int. 2011;22(8):2225–40.

    Article  Google Scholar 

  16. Mendu K, Kataruka A, Puthuvelil J, Akono AT. Fragility assessment of bovine cortical bone using scratch tests. J Vis Exp. 2017;129: e56488.

    Google Scholar 

  17. Deuerling JM, Yue WM, Orias AAE, Roeder RK. Specimen-specific multi-scale model for the anisotropic elastic constants of human cortical bone. J Biomech. 2009;42(13):2061–7.

    Article  Google Scholar 

  18. Kraiem T, Barkaoui A, Merzouki T, Chafra M. Computational approach of the cortical bone mechanical behavior based on an elastic viscoplastic damageable constitutive model. Int J Appl Mech. 2020;12(7):2050081.

    Article  Google Scholar 

  19. Najafi AR, Arshi AR, Eslami MR, Fariborz S, Moeinzadeh MH. Micromechanics fracture in osteonal cortical bone: a study of the interactions between microcrack propagation, microstructure and the material properties. J Biomech. 2007;40(12):2788–95.

    Article  Google Scholar 

  20. Zhang R, Gong H, Zhu D, Ma RS, Fang J, Fan YB. Multi-level femoral morphology and mechanical properties of rats of different ages. Bone. 2015;76:76–87.

    Article  Google Scholar 

  21. Zhang M, Gong H. Translation of engineering to medicine: a focus on finite element analysis. J Orthop Transl. 2020;20(S1):1–2.

    MathSciNet  Google Scholar 

  22. Liu ZH, Gao JZ, Gong H. Effects of treadmill with different intensities on bone quality and muscle properties in adult rats. Biomed Eng Online. 2019;18:107.

    Article  Google Scholar 

  23. Khor F, Cronin DS, Watson B. Importance of asymmetry and anisotropy in predicting cortical bone response and fracture using human body model femur in three-point bending and axial rotation. J Mech Behav Biomed Mater. 2018;87:213–29.

    Article  Google Scholar 

  24. Dapaah D, Badaoui R, Bahmani A, Montesano J, Willett T. Modelling the micro-damage process zone during cortical bone fracture. Eng Fract Mech. 2020;224: 106811.

    Article  Google Scholar 

  25. PinNg T, Koloor SSR, Djuansjah JRP, AbdulKadir MR. Assessment of compressive failure process of cortical bone materials using damage-based model. J Mech Behav Biomed Mater. 2017;66:1–11.

    Article  Google Scholar 

  26. Zhang TL, Gao JZ, Fang J, Gong H. Multiscale investigation on the effects of additional weight bearing in combination with low-magnitude high-frequency vibration on bone quality of growing female rats. J Bone Miner Metab. 2018;36(2):157–69.

    Article  Google Scholar 

  27. Maghami E, Moore JP, Josephson TO, Najafi AR. Damage analysis of human cortical bone under compressive and tensile loadings. Comput Method Biomec. 2022;25(3):342–57.

    Article  Google Scholar 

  28. Zhang GJ, Xu SY, Yang J, Guan FJ, Cao LB, Mao HJ. Combining specimen-specific finite-element models and optimization in cortical-bone material characterization improves prediction accuracy in three-point bending tests. J Biomech. 2018;76:103–11.

    Article  Google Scholar 

  29. Cai XR, Follet H, Peralta L, Gardegaront M, Farlay D, Gauthier R, Yu BL, Gineyts E, Olivier C, Langer M, Gourrier A, Mitton D, Peyrin F, Grimal Q, Laugier P. Anisotropic elastic properties of human femoral cortical bone and relationships with composition and microstructure in elderly. Acta Biomater. 2019;90:254–66.

    Article  Google Scholar 

  30. Fan RX, Liu J, Jia ZB. Effects of different numerical methods on the fracture prediction accuracy for cortical bone structure under bending load. Appl Sci Basel. 2023;13:3998.

    Article  Google Scholar 

  31. Cluzel C, Allena R. Modelling of anisotropic cortical bone based on degradation mechanism. Comput Method Biomec. 2015;18(S1):1914–5.

    Article  Google Scholar 

  32. Kumar A, Shitole P, Ghosh R, Kumar R, Gupta A. Experimental and numerical comparisons between finite element method, element-free Galerkin method, and extended finite element method predicted stress intensity factor and energy release rate of cortical bone considering anisotropic bone modelling. Proc Inst Mech Eng H. 2022;233(8):823–38.

    Article  Google Scholar 

  33. Gaziano P, Falcinelli C, Vairo G. A computational insight on damage-based constitutive modelling in femur mechanics. Eur J Mech A Solids. 2022;93: 104538.

    Article  MathSciNet  MATH  Google Scholar 

  34. Gao X, Chen MH, Yang XG, Harper L, Ahmed I, Lu JW. Simulating damage onset and evolution in fully bio-resorbable composite under three-point bending. J Mech Behav Biomed Mater. 2018;81:72–82.

    Article  Google Scholar 

  35. Kumar A, Ghosh R. A review on experimental and numerical investigations of cortical bone fracture. Proc Inst Mech Eng H. 2022;236(3):297–319.

    Article  Google Scholar 

  36. Li S, Demirci E, Silberschmidt VV. Variability and anisotropy of mechanical behavior of cortical bone in tension and compression. J Mech Behav Biomed Mater. 2013;21:109–20.

    Article  Google Scholar 

  37. Fan RX, Gong H, Zhang R, Gao JZ, Jia ZB, Hu YJ. Quantification of age-related tissue-level failure strains of rat femoral cortical bones using an approach combining macrocompressive test and microfinite element analysis. J Biomech Eng. 2016;138: 041006.

    Article  Google Scholar 

  38. Yang HS, Butz KD, Duffy D, Niebur GL, Nauman EA, Main RP. Characterization of cancellous and cortical bone strain in the in vivo mouse tibial loading model using microCT-based finite element analysis. Bone. 2014;66:131–9.

    Article  Google Scholar 

Download references

Acknowledgements

The work was supported by the higher education basic science (natural science) research project of Jiangsu Province (23KJD580005).

Funding

The work was supported by the higher education basic science (natural science) research project of Jiangsu Province (23KJD580005).

Author information

Authors and Affiliations

Authors

Contributions

RXF, JL and ZBJ designed the FE analysis and interpreted the data; RXF and JL created the FE models and conducted the statistical analysis; ZBJ complied the Abaqus User Material (UMAT) subroutine. RXF, JL and ZBJ wrote the paper. All authors participated in the FE investigation, and provided the feedback on drafts of the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Ruoxun Fan.

Ethics declarations

Ethics approval and consent to participate

This study was approved by the Medical Ethics Committee of the First Hospital of Jilin University (No. 2018-238). This study was in strict accordance with the requirement of the Laboratory Animal Standardization Committee.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Fan, R., Liu, J. & Jia, Z. Effects of different running intensities on the micro-level failure strain of rat femoral cortical bone structures: a finite element investigation. BioMed Eng OnLine 22, 89 (2023). https://doi.org/10.1186/s12938-023-01151-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12938-023-01151-6

Keywords