Study | Method | Eyeball | Pressurization rate (MPa/s) | Ruptured IOP (MPa) |
---|---|---|---|---|
Kennedy et al. [39] | Intraocular compression | Human eyeball | 2.77 ± 0.58 | 0.91 ± 0.29 |
0.02 ± 0.01 | 0.36 ± 0.20 | |||
Porcine | 2.77 ± 0.58 | 1.64 ± 0.32 | ||
0.02 ± 0.01 | 1.00 ± 0.18 | |||
Bisplinghoff et al. [40] | Intraocular compression | Human eyeball | 36.50 ± 15.35 | 0.97 ± 0.29 |
Burnstein et al. [41] | Intraocular compression | Human eyeball | 0.006 | 0.46 ± 0.12 |
porcine | 0.53 ± 0.10 |