Skip to main content

Table 2 Classification performance of different methods on Cataract101

From: Global–local multi-stage temporal convolutional network for cataract surgery phase recognition

Methods

Accuracy

Precision

Recall

Jaccard

ResNet50 [33]

0.864

0.828

0.823

0.710

Qi et al. [34]

0.881

-

-

-

OHFM [23]

0.920

0.892

0.903

0.816

SV-RCNet [22]

0.934

0.913

0.922

0.848

TeCNO [20]

0.936

0.917

0.915

0.847

STANet [21]

0.953

0.934

0.935

0.879

GL-MSTCN

0.965

0.949

0.952

0.908