Table 1 The maximal values of WSS during peak systole in the stenosis (\(\hbox {WSS}_{{\mathrm{st}}}\)), spatially averaged values of WSS during peak systole (\(\hbox {WSS}_{{\mathrm{mean}}}\)) and its standard deviation for the simplified phantom for MRI, \(\hbox {DCFD}_{0.7\times 0.7\times 1.5 \,{\mathrm{mm}}^3}\), \(\hbox {DCFD}_{0.2\times 0.2\times 0.2\,{\mathrm{mm}}^3}\), original CFD, and the peak shift (normalized by the inlet diameter \(d_0\)) in MRI and downsized CFD (with respect to the original CFD)

From: Assessment of turbulent blood flow and wall shear stress in aortic coarctation using image-based simulations

 

\(\hbox {WSS}_{{\mathrm{st}}}\) [Pa]

\(\hbox {WSS}_{{\mathrm{mean}}}\) [Pa]

Standard deviation [Pa]

Peak shift\(^{*}\) [−]

MRI

0.60

0.18

0.09

\(0.39\textit{d}_{0}\)

\(\hbox {DCFD}_{0.7\times 0.7\times 1.5 \,{\mathrm{mm}}^3}\)

1.10

0.25

0.17

\(0.22\textit{d}_{0}\)

\(\hbox {DCFD}_{0.2\times 0.2\times 0.2 \,{\mathrm{mm}}^3}\)

2.35

0.45

0.41

\(0.11\textit{d}_{0}\)

CFD

4.99

0.68

0.80

-

  1. \(^{*}\)The shift is calculated with respect to the original resolution CFD