Table 4 MAE (mean absolute error), precision, recall, and F1-score provided by inter and intra-subject approach using a time tolerance T = 50 ms

From: Intra-subject approach for gait-event prediction by neural network interpretation of EMG signals

Subject MAE (ms) Precision Recall F1-score
Inter Intra Inter Intra Inter Intra Inter Intra
HS mean 13.2 10.9 0.93 0.95 0.92 0.95 0.93 0.95
SD 5.6 2.5 0.06 0.04 0.06 0.04 0.06 0.04
TO mean 21.8 14.6 0.79 0.89 0.78 0.88 0.78 0.89
SD 8.2 4.0 0.20 0.10 0.20 0.11 0.20 0.10