Skip to main content

Table 4 Comparison of heart rate variability between research group and control group

From: Ambulatory blood pressure monitoring in children suffering from orthostatic hypertension

Indicator

Control group

Research group

t

P

SDNN (ms)

121.31 ± 32.54

154.23 ± 9.56

3.795

0.000

SDANN (ms)

122.96 ± 5.40

142.68 ± 3.21

4.127

0.002

rMSSD (ms)

76.08 ± 3.21

77.52 ± 3.62

1.238

0.301

pNN50 (%)

26.30 ± 4.52

27.51 ± 2.36

1.542

0.181

CV

0.12 ± 0.000

0.12 ± 0.000

0.310

0.823

TP

9532.21 ± 452.13

12,311.25 ± 411.23

3.421

0.001

ULF

4231.10 ± 369.21

6987.48 ± 398.41

4.259

0.000

VLF

2896.41 ± 231.41

3961.80 ± 357.12

2.361

0.010