Skip to main content

Table 3 FWHM and PSL for the point at z = 40.0 mm and contrast parameters in the phantom experiment

From: Sidelobe reduction for plane wave compounding with a limited frame number

Beamformer

FWHM (mm)

PSL (dB)

CR (dB)

CNR

Normal PWC

0.68

− 19.46

14.20

1.64

SVD filter

0.68

− 24.22

15.27

1.79

Our method

0.67

− 27.35

16.11

1.81