Table 2 Segmentation information such as segmentation software, time taken for segmentation, and segmentation method for each participant

From: Interlaboratory comparison of femur surface reconstruction from CT data compared to reference optical 3D scan

  Segmentation software Time (min) Segmentation method
Laboratory 1 Mimics 18 480 Semi-automatic + manuel editing (3-Matic v.10)
Laboratory 2A AMIRA® v.5.3.3 480 Semi-automatic + manuel editing (MeshLab 1.3.4)
Laboratory 2B YaDiv 1.0 beta 5 480 Semi-automatic + manuel editing (MeshLab 1.3.4)
Laboratory 3 AMIRA® v.5.4.1 600 Semi-automatic + manuel editing
Laboratory 4 AMIRA® v.6 330 Semi-automatic + manuel editing (Geomagic Studio v.2012)
Laboratory 5 AMIRA® v.5.6 480 Semi-automatic + manuel editing (Geomagic Studio v.2012)
Laboratory 6 Fiji-Medtool v.4.0 85 Full-automatic + manual editing
Laboratory 7A AMIRA® v.5.4.1 270 Semi-automatic + manuel editing (Geomagic Studio v.2013)
Laboratory 7B Mimics v.17 340 Semi-automatic + manuel editing (3-Matic v.9)