From: Automatic QRS complex detection using two-level convolutional neural network
Method | 105 | 108 | 121 | 200 | 202 | 217 |
---|---|---|---|---|---|---|
This work | 0.47 | 0.00 | 0.00 | 0.23 | 0.00 | 0.59 |
Zidelmal et al. [14] | 1.24 | 2.44 | 0.16 | 0.23 | 0.09 | 0.23 |
Arbateni and Bennia [27] | 0.23 | 0.51 | 0.16 | 0.31 | 0.33 | 0.64 |
Kholkhal and Reguig [23] | 0.37 | 0.53 | 0.11 | 0.37 | 0.05 | 0.14 |
Zhou et al. [18] | 1.48 | 2.72 | 0.05 | 0.66 | 0.28 | 0.09 |
Bouaziz et al. [4] | 0.81 | 8.40 | 0.10 | 0.30 | 0.09 | 0.23 |
Phukpattaranont [16] | 1.59 | 4.08 | 0.00 | 0.19 | 0.00 | 0.27 |
Farashi [17] | 2.60 | 2.95 | 0.16 | 0.81 | 1.17 | 0.27 |
Hamdi et al. [15] | 0.04 | 0.11 | 0.27 | 0.00 | 1.17 | 0.09 |