Skip to main content

Table 4 The SNR comparison of the synthetic images corrupted by speckle and Gaussian noise under different noise levels (dB)

From: Rayleigh-maximum-likelihood bilateral filter for ultrasound image enhancement

Noise image

SNR = 15 dB

SNR = 12 dB

SNR = 10 dB

SNR = 7 dB

SNR = 5 dB

SNR = 3 dB

SNR = 1 dB

Proposed

27.7353

28.3570

28.3151

25.0501

21.7660

19.7310

17.5150

SBF

21.9157

18.7967

16.6018

13.7071

11.8087

9.9209

7.8395

Median

20.7309

17.6163

15.4225

11.3534

10.2713

8.0520

5.6002

SRAD

25.5620

22.8780

17.9199

11.3920

7.9691

5.1211

2.5685

NL-means

17.8788

17.7779

17.7091

17.4288

17.1081

16.8585

15.1291

LEE

18.5462

18.2778

16.7909

15.1985

13.4685

12.1603

10.1315

Kuan

23.5905

21.8682

19.6651

13.0058

8.8894

5.7629

3.2307