Skip to main content

Table 2 The PSNR comparison of the synthetic images corrupted by speckle under different noise levels (dB)

From: Rayleigh-maximum-likelihood bilateral filter for ultrasound image enhancement

Noise image

SNR = 15 dB

SNR = 12 dB

SNR = 10 dB

SNR = 7 dB

SNR = 5 dB

SNR = 3 dB

SNR = 1 dB

Proposed

40.0128

40.1669

39.9244

37.6524

35.2580

33.4122

31.1031

SBF

31.4337

28.1467

25.9877

22.9204

21.0456

18.9869

17.0807

Median

28.8297

26.1794

24.2668

21.3757

19.4888

17.2021

14.7029

SRAD

40.5927

35.3693

28.4001

20.6506

17.1747

14.0807

11.6757

NL-means

28.6967

28.5895

28.4449

28.0558

27.8197

27.1815

25.5873

Lee

35.0228

33.1100

31.9598

30.6620

30.0365

29.6552

29.0178

Kuan

29.3561

28.0564

26.8034

24.7770

23.1643

21.1534

19.3770