Skip to main content

Table 1 Application on several real ECG signals issued from the standard database MIT-BIH, extraction of QRS complex, sensitivity and specificity rates determination

From: Real time QRS complex detection using DFA and regular grammar

Record

Record length

Real number of QRS

TP

FN

FP

Se (%)

Sp (%)

FDR

(%)

FNR

(%)

\(\overline{\text{RR}}\)

σRR

\(\overline{\text{QRS}}\)

σQRS

100

1805

2273

2272

1

0

99.96

100.00

0.00

0.04

0.79

0.05

0.05

0.00

101

1805

1865

1864

1

0

99.95

100.00

0.00

0.05

0.96

0.07

0.06

0.00

102

1805

2187

2183

4

2

99.82

99.91

0.09

0.18

0.83

0.09

0.14

0.01

103

1805

2084

2082

2

2

99.90

99.90

0.10

0.10

0.86

0.05

0.05

0.00

104

1805

2230

2211

19

24

99.15

98.93

1.07

0.85

0.81

0.08

0.04

0.04

105

1805

2572

2571

1

0

99.96

100.00

0.00

0.04

0.70

0.11

0.07

0.00

106

60

67

67

0

0

100.00

100.00

0.00

0.00

0.88

0.09

0.06

0.00

107

60

70

70

0

2

100.00

97.22

2.78

0.00

0.82

0.12

0.12

0.02

108

1805

1763

1761

2

0

99.89

100.00

0.00

0.11

1.02

0.21

0.09

0.08

109

1805

2532

2526

6

2

99.76

99.92

0.08

0.24

0.71

0.05

0.09

0.00

111

60

69

69

0

0

100.00

100.00

0.00

0.00

0.89

0.15

0.05

0.01

112

1805

2539

2537

2

6

99.92

99.76

0.24

0.08

0.71

0.03

0.06

0.00

113

1805

1794

1794

0

1

100.00

99.94

0.06

0.00

1.00

0.09

0.05

0.00

114

60

54

54

0

0

100.00

100.00

0.00

0.00

1.10

0.04

0.03

0.00

115

1805

1953

1953

0

0

100.00

100.00

0.00

0.00

0.92

0.08

0.05

0.00

116

60

78

78

0

0

100.00

100.00

0.00

0.00

0.76

0.01

0.06

0.00

117

1805

1535

1534

1

1

99.93

99.93

0.07

0.07

1.17

0.05

0.06

0.00

118

1805

2275

2275

0

12

100.00

99.48

0.52

0.00

0.78

0.10

0.07

0.00

119

1805

1987

1987

0

0

100.00

100.00

0.00

0.00

0.90

0.25

0.07

0.02

121

1805

1863

1861

2

3

99.89

99.84

0.16

0.11

0.96

0.09

0.08

0.00

122

1805

2476

2475

1

2

99.96

99.92

0.08

0.04

0.72

0.04

0.07

0.00

123

1805

1518

1517

1

4

99.93

99.74

0.26

0.07

1.18

0.12

0.06

0.00

124

60

49

49

0

0

100.00

100.00

0.00

0.00

1.21

0.02

0.07

0.01

200

60

87

87

0

0

100.00

100.00

0.00

0.00

0.72

0.40

0.09

0.01

201

60

90

90

0

0

100.00

100.00

0.00

0.00

0.66

0.13

0.06

0.00

202

1805

2136

2111

25

0

98.83

100.00

0.00

1.17

0.85

0.30

0.07

0.00

203

60

97

97

0

0

100.00

100.00

0.00

0.00

0.61

0.24

0.08

0.01

205

60

89

89

0

0

100.00

100.00

0.00

0.00

0.66

0.01

0.05

0.00

207

1805

1862

1859

3

0

99.84

100.00

0.00

0.16

0.96

0.21

0.07

0.09

208

60

87

87

0

0

100.00

100.00

0.00

0.00

0.69

0.26

0.07

0.02

209

1805

3004

3002

2

7

99.93

99.77

0.23

0.07

0.59

0.08

0.05

0.00

210

1805

2647

2606

41

9

98.45

99.66

0.34

1.55

0.69

0.13

0.07

0.01

212

1805

2748

2748

0

5

100.00

99.82

0.18

0.00

0.65

0.04

0.06

0.00

213

1805

3251

3243

8

2

99.75

99.94

0.06

0.25

0.55

0.04

0.06

0.01

214

1805

2262

2229

33

0

98.54

100.00

0.00

1.46

0.81

0.22

0.07

0.00

215

1805

3363

3337

26

0

99.23

100.00

0.00

0.77

0.54

0.09

0.06

0.00

217

1805

2208

2206

2

0

99.91

100.00

0.00

0.09

0.88

0.25

0.10

0.01

219

1805

2154

2152

2

0

99.91

100.00

0.00

0.09

0.83

0.22

0.06

0.00

220

1805

2048

2047

1

4

99.95

99.80

0.20

0.05

0.88

0.09

0.05

0.00

221

1805

2427

2400

27

0

98.89

100.00

0.00

1.11

0.75

0.20

0.06

0.01

222

60

75

75

0

0

100.00

100.00

0.00

0.00

0.81

0.12

0.05

0.00

223

60

80

80

0

0

100.00

100.00

0.00

0.00

0.75

0.08

0.07

0.00

228

60

68

68

0

0

100.00

100.00

0.00

0.00

0.86

0.27

0.07

0.01

230

1805

2256

2219

37

0

98.36

100.00

0.00

1.64

0.81

0.18

0.06

0.00

231

60

63

63

0

0

100.00

100.00

0.00

0.00

0.94

0.11

0.06

0.00

232

1805

1780

1747

33

4

98.15

99.77

0.23

1.85

1.03

0.65

0.06

0.00

233

60

94

94

0

0

100.00

100.00

0.00

0.00

0.58

0.13

0.07

0.01

234

1805

2753

2752

1

0

99.96

100.00

0.00

0.04

0.65

0.03

0.06

0.00

Total

58,720

7,3562

73,278

284

92

99.74

99.86

0.14

0.26

0.82

0.13

0.07

0.01

  1. The average sensitivity (Se) rate of the proposed method was 99.74% and the average specificity (Sp) rate was 99.86%. The average False Detection Rate (FDR) rate and the average False Negative Rate (FNR) rate were 0.14 and 0.26% respectively