Skip to main content

Table 3 Performance of diamond-shaped stent and sv-shaped stent deployed with original and optimal balloon

From: Design optimization of stent and its dilatation balloon using kriging surrogate model

(Unit: mm)

Stents

L

DR

RR

FS

t = 32 ms

t = 42 ms

Proximal

Distal

Diamond stent

 Original

5.1

0.0884

0.0868

0.0205

0.0220

0.2149

 Optimal

4.959

0

0.0016

0.0121

0.0143

0.1974

Sv stent

 Original

6.5

0.0352

0.0363

0.0185

0.0174

0.0571

 Optimal

6.0911

0

0.0027

0.0032

0.0005

0.0475

  1. Diamond-shaped stent: (a) the dogboning effect at 32 ms is completely disappeared and dogboning ratio at 42 ms is decreased by 98.16%. The proximal and distal radial elastic recoil decreases by 40.98 and 35% respectively. Foreshortening was reduced by 1.75%. (b) sv-shaped stent: The dogboning effect at 32 ms is also completely disappeared and dogboning ratio at 42 ms is decreased by 92.56%. The proximal and distal radial elastic recoil decreases by 82.70 and 97.13% respectively. Foreshortening was reduced by 16.81%