Skip to main content

Table 1 Geometrical parameters of extraocular muscles of left eye

From: The biomechanical significance of pulley on binocular vision

 

Origin point (mm) [18]

Insertion point (mm) [18]

Pulley point (mm) [1]

Area (mm2) [15]

x

y

z

x

y

z

x

y

z

LR

−34.00

−13.00

0.60

6.50

10.08

0.00

−11.00

10.02

−0.50

16.73

MR

−30.00

−17.00

0.60

8.84

−9.65

0.00

−5.00

−14.40

−0.60

17.39

SR

−31.76

−16.00

3.60

7.63

0.00

10.48

−7.63

0.00

11.60

11.34

IR

−31.76

−16.00

−2.40

8.02

0.00

−10.24

−7.63

−4.50

−13.00

15.85

SO

8.24

−15.27

12.25

−4.41

2.90

11.05

19.34

IO

11.34

−11.10

−15.46

−7.18

8.70

0.00

19.83