Table 1 Geometrical parameters of extraocular muscles of left eye

From: The biomechanical significance of pulley on binocular vision

  Origin point (mm) [18] Insertion point (mm) [18] Pulley point (mm) [1] Area (mm2) [15]
x y z x y z x y z
LR −34.00 −13.00 0.60 6.50 10.08 0.00 −11.00 10.02 −0.50 16.73
MR −30.00 −17.00 0.60 8.84 −9.65 0.00 −5.00 −14.40 −0.60 17.39
SR −31.76 −16.00 3.60 7.63 0.00 10.48 −7.63 0.00 11.60 11.34
IR −31.76 −16.00 −2.40 8.02 0.00 −10.24 −7.63 −4.50 −13.00 15.85
SO 8.24 −15.27 12.25 −4.41 2.90 11.05 19.34
IO 11.34 −11.10 −15.46 −7.18 8.70 0.00 19.83
\