Skip to main content

Table 5 Calculated radiant exposure lamp–sun equivalences (in “days of use”) for different scenarios and for a decreasing distance d (mm) between the lamp and sunglasses

From: Equivalence between solar irradiance and solar simulators in aging tests of sunglasses

 

Distance (d) from lamp (mm)

300

250

200

150

100

50

From peak to peak

 Min

2

3

5

9

19

78

 Max

7

10

16

28

63

252

 Med

3

4

7

12

27

107

From sunrise to sunset

 Min

2

2

4

6

14

57

 Max

2

3

5

9

21

84

 Med

2

3

4

7

16

62

First band peak only

 Min

14

21

32

57

129

516

 Max

23

33

52

93

209

836

 Med

16

22

35

62

139

557

  1. The minimum and maximum lamp–sun equivalences are listed. Additionally, the medians of all 110 national capitals from northern hemisphere are shown