Skip to main content

Table 1 AME values and percentage evaluation of proposed method and combination of SIFT + LK tracking

From: Registration of retinal sequences from new video-ophthalmoscopic camera

 

Proposed method Median ± st.dev. [px]

Phase-correlation part only Median ± st.dev. [px]

SIFT + LK tracking Median ± st.dev. [px]

Inside the ONH

0.78 ± 0.67

0.92 ± 0.78

0.82 ± 0.87

Outside the ONH

1.39 ± 0.63

1.62 ± 0.72

1.52 ± 0.73

# values <1 px (%)

33

28

30

# values between 1 and 2 px (%)

50

49

47

# values >2 px (%)

17

23

23