Skip to main content

Table 2 Test-retest reliability of the submaximal performance parameters from the RATT, cycle and treadmill

From: Submaximal cardiopulmonary thresholds on a robotics-assisted tilt table, a cycle and a treadmill: a comparative analysis

 

Overall mean (tests 1 and 2)

MD (95 % LoA)

CoV (%)

ICC (95 % CI)

SEM

%SEM

V′O2@VAT (L/min) (n = 9)

 RATT

1.129

−0.047 (−0.225, 0.131)

5.91

0.92 (0.60–0.98)

0.064

5.67

 Cycle ergometer

1.411

0.082 (−0.459, 0.624)

14.10

0.81 (0.39–0.95)

0.195

13.82

 Treadmill

1.561

−0.015 (−0.290, 0.259)

6.78

0.98 (0.90–1.0)

0.099

6.34

V′O2@RCP (L/min)

 

 RATT (n = 6)

1.649

0.094 (−0.208, 0.395)

6.52

0.92 (0.52–0.99)

0.109

6.61

 Cycle ergometer (n = 8)

2.344

−0.014 (−0.706, 0.678)

8.66

0.87 (0.47–0.97)

0.245

10.45

 Treadmill (n = 7)

2.609

−0.069 (−0.640, 0.502)

7.17

0.95 (0.74–0.99)

0.206

7.90

V′E/V′O2@VAT (n = 9)

 RATT

23.7

−0.01 (−3.5, 3.5)

5.02

0.70 (0.10–0.93)

1.26

5.31

 Cycle ergometer

23.4

1.46 (−4.3, 7.2)

9.78

0.62 (0.05–0.90)

2.07

8.87

 Treadmill

21.7

0.20 (−2.5, 2.9)

4.33

0.74 (0.19–0.94)

0.97

4.47

VE/V′CO2@RCP

 RATT (n = 6)

28.8

0.70 (−1.0, 2.4)

2.48

0.77 (0.03–0.97)

0.62

2.16

 Cycle ergometer (n = 8)

27.7

1.24 (−1.2, 3.6)

4.80

0.90 (0.33–0.98)

0.86

3.10

 Treadmill (n = 7)

26.4

−0.97 (−4.6, 2.6)

5.23

0.71 (0.09–0.94)

1.30

4.92

V′E-vs-V′CO2 slope to RCP

 RATT (n = 6)

28.0

0.73 (−4.0, 5.5)

6.00

0.53 (−0.38–0.92)

1.71

6.11

 Cycle ergometer (n = 8)

26.4

2.19 (−2.0, 6.4)

8.26

0.75 (0.04–0.95)

1.52

5.77

 Treadmill (n = 7)

25.4

−1.14 (−4.3, 2.1)

5.13

0.74 (0.12–0.95)

1.15

4.54

  1. MD mean difference, LoA limits of agreement, CoV coefficient of variation, ICC intraclass correlation coefficient, CI confidence interval, SEM standard error of the measurement