Table 7 Performance comparison of results on pathological retinal images on STARE database
From:
A framework for retinal vasculature segmentation based on matched filters
Methods
Sen
Spe
Acc
2nd human observer
0.8719
0.9384
0.9324
Hoover et al. [
15
]
0.6587
0.9565
0.9258
Soares et al. [
35
]
0.7181
0.9765
0.9500
Fraz et al. [
41
]
0.7262
0.9764
0.9511
Proposed method
0.7001
0.9823
0.9539