Skip to main content

Table 5 Results obtained from the twenty test cases of the EXACT’09 project

From: Optimizing parameters of an open-source airway segmentation algorithm using different CT images

 

Branch count

Branch detected (%)

Tree length (cm)

Tree length detected (%)

Leakage count

Leakage volume (mm3)

False positive rate (%)

Case 21

98

49.2

51.1

46.2

1

0.2

<0.01

Case 22

141

36.4

98.6

29.8

13

77.7

0.60

Case 23

126

44.4

90.5

34.8

12

119.8

1.02

Case 24

72

38.7

57.0

35.1

23

245.9

1.82

Case 25

108

46.2

82.7

32.8

5

29.2

0.20

Case 26

32

40.0

21.6

32.8

2

226.3

7.53

Case 27

41

40.6

30.1

37.1

0

0.0

0.00

Case 28

69

56.1

47.7

43.6

0

0.0

0.00

Case 29

93

50.5

62.2

45.0

1

9.0

0.12

Case 30

79

40.5

57.0

37.3

0

0.0

0.00

Case 31

99

46.3

70.3

40.0

2

73.9

0.74

Case 32

89

38.2

73.2

33.6

2

29.9

0.26

Case 33

85

50.6

62.1

42.2

0

0.0

0.00

Case 34

264

57.6

195.7

54.7

16

89.5

0.41

Case 35

146

42.4

108.9

35.2

1

23.7

0.19

Case 36

121

33.2

122.8

29.8

2

2.6

0.03

Case 37

64

34.6

54.4

30.6

1

2.7

0.03

Case 38

37

37.8

27.3

41.1

3

4.0

0.08

Case 39

113

21.7

97.6

23.8

5

92.0

1.01

Case 40

102

26.2

91.2

23.6

5

21.5

0.17

Mean

99.0

41.6

75.1

36.5

4.7

52.4

0.71

SD

50.3

9.0

39.4

7.6

6.3

73.3

1.67

Min

32

21.7

21.6

23.6

0

0.0

0.00

1st quartile

69

36.4

51.1

30.6

1

0.2

<0.01

Median

96

40.6

66.2

35.1

2

22.6

0.18

3rd quartile

126

50.5

98.6

43.6

12

92.0

1.01

Max

264

57.6

195.7

54.7

23

245.9

7.53