Table 4 Test settings: main EOG-SG parameters

From: Envelope filter sequence to delete blinks and overshoots

Pars.

Tests 1–3

Test 4

Test 5

Test 6

Test 7

Test 8

K

100

0

1,000

125

1

1,000

L

1

0

1

[6, 10]

1,000

1

A (º)

±40

0

±40

±15

±40

±40

ρ

[0.9, 1.1]

0

[0.9, 1.1]

[0.9, 1.1]

[0.9, 1.1]

[0.9, 1.1]

m

0

0

0

0

0

[0, 0.05]–[0.35, 0.40]

TSS (s)

[0.6, 1.5]

0

[0.3, 0.4]–[1.4, 1.5]

[0.3, 0.4]–[1.4, 1.5]

[0.3, 0.4]–[1.4, 1.5]

[0.6, 1.5]

9h (s)

[0.3, 0.55]

[0.1, 0.2]–[0.4, 0.5]

0

0

0

[0.3, 0.55]

  1. Settings of tests. Square brackets mean random variations. Meaning of acronyms in the order of appearance.