Figure 4 | BioMedical Engineering OnLine

Figure 4

From: Spatial temperature distribution in human hairy and glabrous skin after infrared CO2 laser radiation

Figure 4

The figure illustrates the spatial surface temperature profile at stimulus end (maximum surface temperature) for both mean experimental data (Exp. data) and modeled temperatures based on a finite element model (FEM). A) glabrous skin, 1 W, 0.6 s, 0.6 J/cm2 B) hairy skin, 1 W, 0.6 s, 0.6 J/cm2 C) glabrous skin, 5 W, 0.12 s, 0.6 J/cm2 D) hairy skin, 5 W, 0.12 s, 0.6 J/cm2. In all plots, it is seen that the temperature change 0.6 cm from the beam center at stimulus termination was less than 5°C. Even though the maximum temperature (at the beam center, 0 cm) for the 5 W power setting was approximately the double of the 1 W power setting, the measured and simulated temperature changes more than 0.5 cm from the beam center was identical.