Skip to main content

Table 2 Quantitative comparison between the proposed approach and alternative methods from the literature.

From: Semi-automatic algorithm for construction of the left ventricular area variation curve over a complete cardiac cycle

 

image quality

number of images

RMSd

CCC

PE (%)

ES (%)

Proposed method

high

20

2.14 ± 0.367

0.985 ± 0.011

2.49 ± 2.46

9.62 ± 7.9

 

average

23

2.53 ± 0.398

0.901 ± 0.024

7.56 ± 2.51

16.20 ± 8.23

 

low

17

2.99 ± 0.695

0.734 ± 0.101

15.10 ± 7.98

18.59 ± 7.02

Klingler Jr et al. [2]

acceptablea

121b

 

0.93

  

Choy and Jin [3]

high

10

1.7 ± 0.7

   
 

average

8

3.5 ± 1.0

   

Lacerda et al. [8]

high

7

  

10.65 ± 2.47

18.51 ± 5.06

 

average

5

  

18.06 ± 7.49

24.62 ± 7.89

Amorim et al. [10]

high

8

 

0.917

 

10.79 ± 2.95

  1. a canine models;
  2. b composite images, each obtained by averaging over ten cardiac cycles.