Figure 7From: Atrial fibrillation detection by heart rate variability in Poincare plotPoincaré plot when the QRS detector misses one. (a) The QRS detector missed one QRS complex. (b) Poincaré plot made from the wrong inter-beat intervals. We can find that the detector did not catch one QRS complex by investigating the Poincaré plot.Back to article page