Skip to main content

Table 1 Results of validation using artificial time series.

From: Analysis of induced components in electroencephalograms using a multiple correlation method

  SNR μ RMSE σ RMSE
before multiple correlation analysis   30.57 4.03
after multiple 10: 1 3.67 1.87
correlation analysis 5: 1 3.97 1.50
  2.5: 1 3.54 1.65
  2: 1 3.81 1.59
  1: 1 4.12 1.64
  0.5: 1 4.39 1.32
  0.25: 1 5.28 1.24
  1. Mean μ and standard deviation σ of the RMSE of the known phase-shift parameters before correction and the remaining phase-shift after multiple correlation analysis.