Skip to main content

Table 3 The results of modelling for the renal stenosis. The values of pressure drops (obtained by CFD), compliances (obtained by the mathematics) and final Diastolic/Systolic pressures of the renal with stenosis (obtained by electrical system). Please note that the values are approximate.

From: Modeling of the aorta artery aneurysms and renal artery stenosis using cardiovascular electronic system

Renal (Dia = 2.6 mm, L = 32 mm)

ΔP(Pa) Stenosis

C(ml/Kpa) Stenosis

Diastol/Systole Pressure(mmHg)

20% Stenosis

7.46

0.01512

82–121

50% Stenosis

17.1

0.0236

85–127

70% Stenosis

75

0.116

97–148

90% Stenosis

3790

0.136

145–210