Skip to main content

Table 2 Comparison between the dimensional and the dimensionless implementation of MINMOD. Results are from 100 Monte Carlo simulations.

From: Dimensional analysis of MINMOD leads to definition of the disposition index of glucose regulation and improved simulation algorithm

Comparisons

Dimensional

Dimensionless

Significance

Number of iterations

8.0 ± 1.4

6.4 ± 2.7

P < 0.001

R 2

0.97 ± 0.02

0.97 ± 0.03

N.S

p 1 % difference from true value

(53.2 ± 7.6)%

(53.2 ± 9.6)%

N.S.

p 1, FSD of estimation

(14.1 ± 2.7)%

(14.9 ± 6.0)%

N.S

p 2, % difference from true value

(188 ± 160)%

(187 ± 155)%

N.S.

p 2, FSD of estimation

(11.6 ± 1.6)%

(12.1 ± 3.5)%

N.S

p 3, % difference from true value

(513 ± 324)%

(505 ± 317)%

N.S.

p 3, FSD of estimation

(11.6 ± 1.7)%

(12.1 ± 3.5)%

N.S

G 0, % difference from true value

(1.3 ± 0.4)%

(1.3 ± 0.4)%

N.S.

G 0, FSD of estimation

(0.1 ± 0.04)%

(0.1 ± 0.06)%

N.S

S I , % difference from true value

(52.4 ± 25.5)%

(52.1 ± 25.5)%

N.S