Table 3 Sensitivity and specificity at baseline and during cold/warm cycle of temperature difference and the asymmetry factor

From: Thermography imaging during static and controlled thermoregulation in complex regional pain syndrome type 1: diagnostic value and involvement of the central sympathetic system

 

|Average fingertip temperature difference at rest.|

|Max. average fingertip temperature difference during temperature cycle.|

Asymmetry factor at rest.

Minimum Asymmetry factor during the temperature cycle.

Sensitivity

76%

92%

100%

100%

Specificity

38%

75%

75%

83%

Positive predictive value

62

85

100

100

Negative predictive value

43

86

73

79

Cut-off points

0.1°C

1.4°C

0.81

0.73

AUC 95% interval and Std.Error

0.48 0.221–0.737(0.101)

0.87* 0.666–1.063(0.101)

0.90* 0.767–1,035(0.068)

0.96** 0.879–1.038(0.40)

Likelihood ratio positive test

1.2

3.7

4

5.9

Likelihood negative test

0.6

0.1

0

0

Difference in AUC

0.39*

0.06

  1. *Significant at the p < 0.05 level.
  2. **Significant at the p < 0.001 level.