Skip to main content

Table 4 Computation time comparison in seconds

From: Life-threatening ventricular arrhythmia recognition by nonlinear descriptor

Length of episode Hurst index Complexity measure Length of episode Hurst index Complexity measure
1 sec 0.0546 0.0654 1.5 sec 0.0697 0.0824
2 sec 0.0794 0.1143 2.5 sec 0.0933 0.1538
3 sec 0.1168 0.2176 3.5 sec 0.1401 0.2991
4 sec 0.1885 0.4003 4.5 sec 0.2407 0.609
5 sec 0.2803 0.6833 5.5 sec 0.3122 0.7792