Table 1 Exposure Parameters Used With The Model

From: Modeling thermal responses in human subjects following extended exposure to radiofrequency energy

Frequency, MHz

Incident power densities, W/m2 (peak field intensity in beam)

Peak surface specific absorption rate (SAR), W/kg

Total Power Added to Model, W *

100

40, 60, 80

0.26, 0.39, 0.52 (estimated whole body average SAR)

19, 29, 38 (based on 70 kg model)

450

240

7.7 (SAR at surface)

86 (based on 0.68 m2 surface area of torso and parameters in Table 2)

2450

270, 350, 500, 700

5.9, 7.7,11, 14.4 (SAR at surface)

50, 64, 92, 128 (based on 0.68 m2 surface area of torso and parameters in Table 2)

  1. * Basal heat production 86 W