Table 1 Inverse algorithm results.

From: Pulsatile arterial wall-blood flow interaction with wall pre-stress computed using an inverse algorithm

  

In-vivo

(I)

Load-free

(inverse)

Pre-stressed

(P)

% = I - P I × 100

Inner diameter (mm)

Inlet

3.60

3.104

3.604

1.1 × 10-1

 

Outlet

3.60

3.104

3.604

1.1 × 10-1

Outer diameter (mm)

Inlet

4.14

3.974

4.140

0.0

 

Outlet

4.14

3.974

4.140

0.0

Thickness

(mm)

0.270

0.435

0.269

3.7 × 10-1

Length

(mm)

52.0

35.13

51.99

2.0 × 10-2

Volume

(mm3)

170.69

169.90

169.90

4.6 × 10-1

  1. The dimensions of load-free and pre-stressed geometry calculated by the inverse algorithm.