Skip to main content

Table 3 Performance metrics (Sesensitivity%; Spspecificity%; Accaccuracy%)

From: sEMG feature evaluation for identification of elbow angle resolution in graded arm movement

  

2-class set up

3-class set up

5-class set up

  

Se

Sp

Acc

Se

Sp

Acc

Se

Sp

Acc

PSD-Av

Flex

95

95

95

89

94

89

64

91

64

Ext

100

100

100

84

92

84

62

90

62

PSD

Flex

100

100

100

89

94

89

48

87

48

Ext

100

100

100

76

88

76

52

88

52

MAV

Flex

81

78

93

79

87

79

48

87

48

Ext

100

86

98

86

89

86

65

88

65

WL

Flex

100

78

95

76

88

76

50

88

50

Ext

100

86

100

79

90

79

51

88

51

RMS

Flex

85

79

88

62

81

78

51

87

51

Ext

100

86

100

75

87

79

62

88

62

AR

Flex

86

90

88

81

90

81

45

86

45

Ext

100

95

98

73

87

73

55

89

55

PSD-Mo

Flex

100

88

93

68

84

68

41

85

41

Ext

100

100

100

63

82

64

38

85

38

WAMP

Flex

59

50

64

46

72

46

27

82

27

Ext

75

73

79

57

76

57

27

82

28

ZC

Flex

75

68

81

52

73

52

33

82

33

Ext

45

45

50

41

67

41

24

81

24