From: Heart rate variability analysis using robust period detection
LF/HF differences for series with distorted/removed beats | ||||||
---|---|---|---|---|---|---|
LF/HF for undistorted series | RPDdis | RPDrem | LSPdis | LSPrem | FFTdis | FFTrem |
0.1 | 17% | 9% | -31% | 63% | 2% | 36% |
0.3 | 10% | 4% | -62% | 28% | -46% | 28% |
1 | 2% | -1% | -80% | -2% | -73% | 21% |
3 | -4% | -5% | -89% | -23% | -86% | 14% |
10 | -11% | -10% | -94% | -41% | -93% | 8% |