Skip to main content

Table 2 Correlation summary between WTI and FSS at baseline

From: Correlations between carotid plaque progression and mechanical stresses change sign over time: a patient follow up study using MRI and 3D FSI models

Patient

Nodes

TP1-TP2

Nodes

TP2-TP3

Nodes

TP3-TP4

p

r

p

r

p

r

P1

800

0.0000

0.7795

800

0.0048

−0.1168

   

P2

800

0.0003

−0.1432

900

0.7463

0.0132

900

0.5646

−0.0157

P3

700

0.0787

−0.0495

800

0.2754

−0.0303

800

0.0000

−0.1859

P4

700

0.8717

0.0074

700

0.0316

−0.0761

   

P5

900

0.0026

−0.1257

900

0.0535

−0.0538

   

P6

800

0.3243

0.0256

800

0.5825

−0.0165

800

0.0757

−0.0459

P7

700

0.0015

−0.1208

400

0.0002

−0.1705

   

P8

400

0.0051

−0.1524

900

0.0909

0.0553

   

P9

700

0.0000

−0.2104

700

0.0012

−0.1732

   

P10

400

0.0003

−0.0749

      

P11

800

0.4927

0.0207

900

0.0003

−0.1034

   

P12

800

0.0000

−0.0900

800

0.2037

−0.0482

800

0.1904

0.0376

P13

600

0.1071

−0.0864

600

0.0281

−0.0865

500

0.6058

0.0355

P14

700

0.6729

0.0127

700

0.4306

−0.0322

600

0.0788

−0.0591

P15

1000

0.8519

−0.0044

1000

0.4461

0.0220

   

P16

900

0.5383

0.0179

800

0.0071

−0.0906

800

0.0082

−0.0853

All

T1-T2

0.0350

−0.0182

T2-T3

0.0003

−0.0308

T3-T4

0.0001

−0.05210

Total

         

P=1

 

16 pairs

P=1

 

15 pairs

P=0

 

7 pairs

P=0

N=16

  

N=7

  

N=7

  

N=2

NS=21

  

NS=8

  

NS=8

  

NS=5

  1. P=Positive; N=Negative; NS=No Significance.
  2. Bold faced cases are cases of statistical significance.